background image

Part No.  320998-0

B

Installation Instructions

Guardall Limited

Lochend Industrial Estate

Newbridge, Edinburgh EH28 8PL

T

e

chnical Hotline: 0131- 333-3802

W
e

bsite: www

.guardall.com

Voltage:

12 V (9 V to 16 V dc)

Current:

Quiescent –  14 mA @ 12V

Max – 30 mA @12V (All LEDs ON)

Alarm, Aux & 
Tamper:

Normally closed (NC). Rated at 24 V dc, 
50mA 

Test Input:

Positive supply to enable LEDs and control 
Remote Self Test

Control Input:

Positive supply for system Set. Otherwise 
Unset

Microwave range:

50% to 100% of range via potentiometer

1. Technical Specifi cation

See datasheet for full information

1

5

7

2

9

6

4

10

3

Diagram 1

 - Unit Explanation

1. 

Cover Screw (loosen only - do not remove)

2. 

Microwave Range Control

3. 

PCB Retaining Screw

4. 

PIR Detector (do not touch)

5. Cover 

Tamper

6. Declination 

Indicator

7. LEDs
8. 

Off the Wall Tamper Connection  

9. Terminal 

Block

10. 

Cable Knockout Positions

9m          

                

0m         

9m

  

        

0m  3m  6m  9m  12m  15m

2.3m

 

Diagram 4

 - Coverage Diagrams

Volumetric Side View 15m 

 

0m  3m  6m  9m  12m  15m

Diagram 2

 - Terminal block 

 1   2   3   4   5   6   7   8   9   10

 

NC Aux 

Ctrl 

12 V

 

Test 

-  

+

NC 

Alarm 

NC

Tamper 

Volumetric Plan View 15m 

Diagram 3

 - Tamper Switch

Off the wall tamper fi tting is required for EN Grade 3 

- the screw should be fi tted in location A or C.

DTSx+

8

Отзывы: