Model: 1165190
O p e r at i O n M a n u a l
The GUARD
TM
Megadetect is a superior handheld metal detector with Ultra-Sensing Technology
designed to meet the exact requirements of the security industry. Typical uses will include body
search for offensive weapons in crowd control, airport and border security, to check parcels and
letters for metal objects or anywhere that hidden metal objects need to be detected.
i n t r O d u c t i O n
TM
O p e r at i O n
The 1165190 operates with one 9V standard or rechargeable battery. To install the battery, slide
off the battery cover and place the battery into it’s compartment while matching the +/- symbols.
Turn the unit on by pushing the on/off switch until the GREEN LED lights up. The detector is now
operational. The sensitivity can be adjusted by pressing and holding the sensitivity button until
the RED LED goes out and the tone fades. The detector is now tuned for optimum sensitivity.
To scan, hold the unit with the detection face towards the surface, sweep backwards and
forwards continuously at a height of about 1 inch above the area.
The presence of metal will be indicated by the audio warning tone and the RED light will come
on. If the detector is held for a while over the metal object the detection signal will reduce
automatically.
~
~
~
~
The sensitivity of the detector is determined primarily by the size , shape and composition of the
object that will be detected.
p e r f O r M a n c e
Press the low sensitivity switch during detection and the scanner will respond only to bigger metal
objects such as a hand gun, knife, etc. It will not respond to small metals such as a coin, key, hat pin,
etc. Do not release the low sensitivity switch until you complete the detection.
l O W s e n s i t i V i t Y M O d e
r e c H a r G e a B l e B at t e r Y s O c K e t
You may use a 9V rechargeable battery.
If using rechargeable battery it takes four to six hours to fully charge the battery. The battery
charger socket is located at the side of the detector.
~
~
NOTE:
Turn off the detector when charging it.
The detector is equipped with a vibration button located on the side of the detector. The vibration
function should be used in noisy work situations or in places where the operator does not wish the
audio alert to be heard in the surrounding area. Press and hold the button to turn it on and release to
turn it off.
V i B r at i O n B u t t O n