Ocean Star
Ⅲ
6P luxury (leisure version) user manual 1.0 7/22/2014
Figure 4.9
Ⅶ
Common faults and solutions
The section is to introduce you the common faults and their solutions of the machine.
Common fault
cause
solution
When machine
energized, no
respond nor
bright screen
1. improper
power
source
1. check power source whether suit for
the machine
2. replace fuse
2. blown fuse
1. check VGA signal
wire whether
properly linked if the
“no signal” reminder
keep showing for
more than one
minute
2. make sure 220VAC power supply and
power switch keep ON, check screen
signal wire whether well connected
When machine
energized, with
normal sound, but
no image nor
raster
Burnout of fuse
1. check working voltage of the scan
panel whether normal or not
2. replace same model fuse
Image shown but
no sound
1. minimum
of
volume 1. turn up the volume
2. damage
of
loudspeaker
2. replace the damaged loudspeaker
1. insert coin again
No respond after
coin inserted
1. coin not completely
inserted
2. replace sample coin in the slot
3. replace slot
2. improper
coin
4. once when connected
3. damaged
slot
5. once when connected
4. drop of slot wire
5. check
whether
voltage of slot mouth
is 2V and d-c
No ticket comes
out and there
shows “no ticket
1. ticket used up
1.refill ticket
2. ticket stuck at the
ticket exit
2.clear ticket exit
3.once when connected
18