- 51 -
5.6.3 Event Handling
The Event Handling feature has five options:
RECORD:
Allows you to set the channel which will start recording once an alarm is
activated. (Choice of 1 to 4, multiple channels can be selected)
PTZ PRESET: Setting PTZ behavior after an alarm is triggered. Only preset point 1 can
be triggered (Choice of Channel 1 to 4, multiple channels can be
selected).
ALARM OUT: Setting the triggered alarm output (ON or OFF options).
BUZZER:
Setting the internal buzzer behavior after an alarm is triggered (ON or
OFF options).
UPLOAD:
Setting the option for sending information about an alarm to the center.
To open the next page press the
Advanced Settings
button in the bottom right corner of
the
Alarm
Tab window.
5.6.4 Event Handling: Alarm E-mail
If you want an email to be sent to the chosen recipients, check this option by clicking
on
Alarm
Æ
Advanced Settings
Æ
button. For information on how to set up
e-mail lists, please refer to
Section 5.5.12 E-Mail Settings
under the
Net
Tab.
Note 1
: before setting alarm triggered record, please set up the record
schedule in
Record Schedule
.
Note 2
: if you want to set alarm triggered PTZ, please ensure preset
point is set and proper PTZ channel number is selected (only preset 1
can be selected)