If the force value at the end of the 5s measurement period (
F
End
)
exceeded 80 N, the LED within the third display segment
flashes.
Measurement result:
F
dyn
= 326 N
F
End
> 80 N
If the force value at the end of the 5s measurement period (
F
End
)
exceeded 25N and the dynamic time (
t
dyn
) exceeded 0.75 s, the
LEDs within the second and the third display segment flash.
Measurement result:
F
dyn
= 326 N
t
dyn
> 0,75 s
F
End
> 25 N