Positioning
1.1
Set final “open“ position
(only in connenction with DES)
save
-.-
Use the internal keys to move to the required “open” position
Stop key
1.2
Set final “close” position
(only in connection with DES
)
save
-.-
Use the internal keys to move to the required “close” position
Stop key
1.3
Fine adjustment of final “open” position
(only in connection with DES)*
Save
-.0
The “open” position can be shifted to “open” or “close” by setting
a value
‾‾.0..9 Shift the “open” position to “open” by x values **
Press rotary switch
_.0..9 Shift the “open” position to “close” by x values ***
1.4
Fine adjustment of final “close” position
(only in connection with DES)*
Save
-.0
The “close” position can be shifted to “open” or “close” by setting
a value
‾‾.0..9 Shift the “close” position to “open” by x values **
Press rotary switch
_.0..9 Shift the “close” position to “close” by x values ***
1.5
Fine adjustment of premature shut down
(only in connection with DES)*
Save
-.0
Shut-down point for safety facilities shortly before the final
“close” position is reached can be shifted to “open” or “close” by
setting a value
‾‾.0..9 Shift position to “open” by x values **
Press rotary switch
_.0..9 Shift position to “close” by x values ***
1.6
Set partial opening
(only in connection with DES)
Save
-.-
Use the internal keys to go to the desired partial opening
position
Stop key
1.7
Switching position Relay K3 Adjustment
(only available with DES)
Save
-.-
Use the internal keys to go to the desired position
Stop key
1.8
Switching position Relay K4 Adjustment
(only available with DES)
Save
-.-
Use the internal keys to go to the desired position
Stop key
5.1
Switching position Relay K5 Adjustment
(only available with DES)
Save
-.-
Use the internal keys to go to the desired position
Stop key
5.2
Switching position Relay K6 Adjustment
(only available with DES)
Save
-.-
Use the internal keys to go to the desired position
Stop key
5.3
Switching position Relay K7 Adjustment
(only available with DES)
Save
-.-
Use the internal keys to go to the desired position
Stop key
5.4
Switching position Relay K8 Adjustment
(only available with DES)
Save
-.-
Use the internal keys to go to the desired position
Stop key
* possible several time **
turn clockwise ***
turn counter-clockwise