background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED Wash Flood Light 

GTD-L6238P 

User’s Manual 

 

 

 

 

 

Guangzhou GTD Lighting Technology Co., Ltd. 

Tel: +86-20-61808296

 

Fax: +86-20-61812282 

http://

www.gtd-lighting.com

 

 

Содержание GTD-L6238P

Страница 1: ...LED Wash Flood Light GTD L6238P User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Страница 2: ...panies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained with...

Страница 3: ... Accessories 5 Product introduction 6 Installation 6 Device installation 6 Power Control connection 7 Power connection 7 Control connection 7 Testing 8 Control panel 8 Menu structure 9 DMX protocol 10 Technical specification 13 Cleaning and maintenance 15 Troubleshooting 16 System wiring diagram 17 Spare parts list 18 Appendix 1 18 ...

Страница 4: ...G Fire hazard It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Before ap...

Страница 5: ...e changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixture is only intended for installation operation and maintenance by qualified p...

Страница 6: ...sories and then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along with all the accessories Close the ...

Страница 7: ...ition on the base of the fixture Warning Use two clamps when mounting the fixture Fasten the screw properly and connect a safety cable to fixture Device installation 1 Make sure there is no damage on the clamps or safety cables before installation 2 The clamps are mounted on the base of the fixture Horizontally insert the clamp into the mounting holes of the base Fasten the clamp tightly by a 1 4 ...

Страница 8: ...fixture is correctly grounded and the electrical installation conforms to all relevant Standards Codes of Practice for Safe Electrical Work Control connection The fixture has 5 pin XLR connectors for DMX data input and output 3 pin optional as shown below Connection between the console and fixture and between fixtures must be made with 2 core screened DMX signal cable Maximum connecting distance o...

Страница 9: ...of the fixture Press UP or DOWN to view or select the function menu Press ENTER to choose a function and enter into corresponding sub menu Each menu represents a specific function of the fixture Press ENTER to select the specific function and save the changes or enter into the submenu then press UP or DOWN to change the value of the selected function increase or decrease Press MENU to return to th...

Страница 10: ...X D 00 DXXX Display the channel value D ON ON OFF Turn on or off the Backlight time function EDDY ON OFF Inverted Display SET RDMX ON OFF Allow the console to change the Address DEFA ON OFF Factory reset FANS AUTO HIGH LOW Setting the Fans status Save OFF 1 99M 15M Close the LED light when no signal Ver V1 0 V9 9 Software version Edit SEPR AUTO IP01 IP10 Selecting the program that want to edit STE...

Страница 11: ...ll light 0 0 3 3 Red 1 0 255 0 0 100 0 No light Full red 1 0 0 4 Red 2 0 255 0 0 100 0 No light Full red 2 0 0 5 4 Green 1 0 255 0 0 100 0 No light Full green 1 0 0 6 Green 2 0 255 0 0 100 0 No light Full green 2 0 0 7 5 Blue 1 0 255 0 0 100 0 No light Full blue 1 0 0 8 Blue 2 0 255 0 0 100 0 No light Full blue 2 0 0 9 6 Rainbow Function1 0 9 0 0 3 5 No function 0 0 10 39 3 9 15 3 Rainbow scene 1 ...

Страница 12: ...7 232 255 91 0 100 0 Rainbow flow from slow to fast 11 7 Color temperature 1 0 24 0 0 9 4 No function 0 0 25 35 9 8 13 7 3200K 36 46 14 1 18 0 3400K 47 57 18 4 22 4 3600K 58 68 22 7 26 7 3800K 69 79 27 1 31 0 4000K 80 90 31 4 35 3 4200K 91 101 35 7 39 6 4400K 102 112 40 0 43 9 4600K 113 123 44 3 48 2 4800K 124 134 48 6 52 5 5000K 135 145 52 9 56 9 5200K 146 156 57 3 61 2 5400K 157 167 61 6 65 5 56...

Страница 13: ...200K 91 101 35 7 39 6 4400K 102 112 40 0 43 9 4600K 113 123 44 3 48 2 4800K 124 134 48 6 52 5 5000K 135 145 52 9 56 9 5200K 146 156 57 3 61 2 5400K 157 167 61 6 65 5 5600K 168 178 65 9 69 8 5800K 179 189 70 2 74 1 6000K 190 200 74 5 78 4 6200K 201 211 78 8 82 7 6400K 212 222 83 1 87 1 6600K 223 233 87 5 91 4 6800K 234 244 91 8 95 7 7000K 245 255 96 1 100 0 7200K Notes Do not switch off the fixture...

Страница 14: ...rotocol DMX 512 Display 4 x 8 segment display Physical Installation Weight 28 kg 62 lbs IP rating IP65 Material Aluminium steel plastic Minimum distance to combustible materials 1 64ft 0 5m Minimum distance to illuminated surfaces 3 28ft 1m Dynamic effects Pan Tilt movement Manually adjustable Strobe 1 25Hz synchronized pulse effects Dimmer 0 100 16 bit electronic linear dimming Thermal Operating ...

Страница 15: ...GTD L6238P User Manual 14 Certification and Safety EMC EN 55103 1 2009 EN 55103 2 2009 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2013 Safety EN 60598 2 17 1989 A2 1991 Photometric ...

Страница 16: ...sing of the fixture If the lens is cracked or otherwise damaged replace it immediately If the LED lamp becomes damaged or deformed in any way it must be replaced If the light from the LED lamp appears dim this normally indicates that it is reaching the end of its life span and should be changed at once Aged LED lamps run to the extremity of their life might explode If fixture does not function che...

Страница 17: ... of the fixture Choose the channel mode in Channel setting Channel Mode of the fixture as required by the user Malfunctioning of DMX cannon input output connectors No input output voltage to the main control board of the fixture Troubleshooting the DMX XLR signal plate of the fixture replace the main control board of the fixture LED lamp off There is no signal output to the main control board PWM ...

Страница 18: ... VCC J2 J4 J8 J5 J4 J3 J5 J4 J3 5802030064B GND VCC LCR0210B J2 J2 JC1 JC2 ESS400 5624P ESS400 5624P 24V GND 56V GND 24V GND 5802010030A JC J1 LJB0217B 5802010030A JC J1 LJB0217B 5802030063B J3 J7 GND VCC LCR0209B 5802020030A J6 FAN1 JF2 JC4 JC3 JF1 FAN2 24V GND Waterproof male female signal cable Fan 4 SDI0200C 1412050028A Switching power supply N L FG 1412050028A N L E N L FG 56V GND ...

Страница 19: ...witching Power Supply 1412050028A 2 EDS400 5624P LED drive board 0209B 1 5802030063B 2 LCR0209B LED drive board 0210B 1 5802030064B 2 LCR0210B LED aluminum substrate 5802010030A 2 LJB0217B Display board 5809210050A 1 L6238P 101E10 102F10 103F10 SDI0200C Appendix 1 ...

Страница 20: ...GTD L6238P User Manual 19 Notes P N 1502011050A Time August 10th 2017 ...

Отзывы: