background image

 

GTD-L3100 User Manual 

12 

DMX mode 

Name 

DMX value 

DMX 

percentage 

Function 

Default 

DMX 

Value 

Standard 

(21ch) 

Basic 

(12ch) 

20 

11 

Color temperature 

24 

0.0% 

9.4% 

No function 

0(0%) 

25 

35 

9.8% 

13.7% 

3200K 

36 

46 

14.1% 

18.0% 

3400K 

47 

57 

18.4% 

22.4% 

3600K 

58 

68 

22.7% 

26.7% 

3800K 

69 

79 

27.1% 

31.0% 

4000K 

80 

90 

31.4% 

35.3% 

4200K 

91 

101 

35.7% 

39.6% 

4400K 

102 

112 

40.0% 

43.9% 

4600K 

113 

123 

44.3% 

48.2% 

4800K 

124 

134 

48.6% 

52.5% 

5000K 

135 

145 

52.9% 

56.9% 

5200K 

146 

156 

57.3% 

61.2% 

5400K 

157 

167 

61.6% 

65.5% 

5600K 

168 

178 

65.9% 

69.8% 

5800K 

179 

189 

70.2% 

74.1% 

6000K 

190 

200 

74.5% 

78.4% 

6200K 

201 

211 

78.8% 

82.7% 

6400K 

212 

222 

83.1% 

87.1% 

6600K 

223 

233 

87.5% 

91.4% 

6800K 

234 

244 

91.8% 

95.7% 

7000K 

245 

255 

96.1% 

100.0%  7200K 

21 

12 

Special controls 

39 

0.0% 

15.3% 

No function 

0(0%) 

40 

59 

15.7% 

23.1% 

Built-in program 1 

60 

79 

23.5% 

31.0% 

Built-in program 2 

80 

99 

31.4% 

38.8% 

Built-in program 3 

100 

119 

39.2% 

46.7% 

Built-in program 4 

120 

139 

47.1% 

54.5% 

Built-in program 5 

140 

159 

54.9% 

62.4% 

Built-in program 6 

160 

179 

62.7% 

70.2% 

Built-in program 7 

180 

199 

70.6% 

78.0% 

Built-in program 8 

200 

219 

78.4% 

85.9% 

Built-in program 9 

220 

239 

86.3% 

93.7% 

Built-in program 10 

240 

255 

94.1% 

100.0%  No function 

  Notes 

Do not switch off the fixture within the first minute after switching on. Wait for at least 5 minutes to switch on the fixture. 

 

Содержание GTD-L3100

Страница 1: ...LED Cyclorama GTD L3100 User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Страница 2: ...anies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained withi...

Страница 3: ... 5 Product introduction 6 Installation 7 Clamps installation 7 Device installation 7 Power Control connection 7 Power connection 7 Control connection 8 Testing 8 Control panel 9 Menu structure 10 DMX protocol 11 Technical specification 13 Cleaning and maintenance 14 Troubleshooting 15 System wiring diagram 16 Spare parts list 17 Appendix 1 17 ...

Страница 4: ...Do not expose fixture for rain and moisture It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be u...

Страница 5: ...anging any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixture is only intended for installation operation and maintenance by qualified profe...

Страница 6: ...oam from the top put away the accessories and then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along ...

Страница 7: ...TD L3100 User Manual 6 Product introduction 1 LED lens 2 Base 3 Clamp mounting position 4 Manually adjustable screw 5 DMX input 6 Power switch 7 Fuse 8 DMX output 9 Power input 10 Power output 11 Display ...

Страница 8: ...he truss Power Control connection Power connection Connection method L Live Brown wire E Earth Yellow Green bi color wire N Neutral Blue wire The voltage and frequency of the power source must be in compliance with the ones marked on the fixture Please apply series connection when many sets of fixtures are connected to the power source to avoid heavy load to the power source When the voltage is 11...

Страница 9: ...commended for longer distance Connect the Console s DMX OUTPUT to the first fixture s DMX INPUT then the first fixture s DMX OUTPUT to the second fixture s DMX INPUT and so on It is recommended not to connect more than 32 units on a single DMX universe On the last fixture s output connect a DMX terminator The terminator is a XLR connector with a W and 120Ω resistor between the pin 2 and pin 3 as s...

Страница 10: ...s ENTER to choose a function and enter into corresponding sub menu Each menu represents a specific function of the fixture Press ENTER to select the specific function and save the changes or enter into the submenu then press UP or DOWN to change the value of the selected function increase or decrease Press MENU to return to the previous menu or exit LED indicators Power on RED power LED indicator ...

Страница 11: ...X D 00 DXXX Display the channel value D ON ON OFF Turn on or off the Backlight time function EDDY ON OFF Inverted Display SET RDMX ON OFF Allow the console to change the Address DEFA ON OFF Factory reset FANS AUTO HIGH LOW Setting the Fans status Save OFF 1 99M 15M Close the LED light when no signal Ver V1 0 V9 9 Software version Edit SEPR AUTO IP01 IP10 Selecting the program that want to edit STE...

Страница 12: ...e fine LSB 4 3 Red 0 255 0 0 100 0 No light Full red 0 0 5 0 65535 0 0 100 0 Red fine LSB 6 4 Orange 0 255 0 0 100 0 No light Full orange 0 0 7 0 65535 0 0 100 0 Orange fine LSB 8 5 Amber 0 255 0 0 100 0 No light Full amber 0 0 9 0 65535 0 0 100 0 Amber fine LSB 10 6 Green 0 255 0 0 100 0 No light Full green 0 0 11 0 65535 0 0 100 0 Green fine LSB 12 7 Cyan 0 255 0 0 100 0 No light Full cyan 0 0 1...

Страница 13: ...200 74 5 78 4 6200K 201 211 78 8 82 7 6400K 212 222 83 1 87 1 6600K 223 233 87 5 91 4 6800K 234 244 91 8 95 7 7000K 245 255 96 1 100 0 7200K 21 12 Special controls 0 39 0 0 15 3 No function 0 0 40 59 15 7 23 1 Built in program 1 60 79 23 5 31 0 Built in program 2 80 99 31 4 38 8 Built in program 3 100 119 39 2 46 7 Built in program 4 120 139 47 1 54 5 Built in program 5 140 159 54 9 62 4 Built in ...

Страница 14: ...Auto ranging electronic SMPS Main fuse 250V 3 15A Control and programming Control channels DMX 21 12 Protocol DMX 512 Display 4 x 8 segment display 16 bit control Dimmer Physical Installation Weight 8kg 17 6 lbs IP rating IP20 Material Aluminum steel plastic Mounting points 12mm holes for G Clamp Minimum distance to combustible materials 1 64ft 0 5m Minimum distance to illuminated surfaces 3 28ft ...

Страница 15: ...e its reliability Its lifespan mainly depends on the working environment and proper operation Should you have any questions please consult a technical engineer of GTD Lighting Notes Damage resulted from dust smoke oil or improper use is not covered by warranty Warning Disconnect the fixture from AC power and let it cool down for at least 15 minutes before opening the housing Make sure to use a sof...

Страница 16: ...e to the commands of the control system DMX cables disconnected from fixture s DATA IN connector Connect DMX cable to the fixture s DATA IN connector Open circuit or short circuit fault in the DMX cables Replace DMX cables as required Wrong DMX address for the fixture in the control system Ensure the address in Run setting Address Setting Address of the fixture is consistent with the address in th...

Страница 17: ... LJB0304D 1407180002A J6 FAN1 N L E power swpply FUSE Switching power supply J3 J2 J1 J1 J2 J3 J4 J8 J6 J5 J7 N L FG JF2 J5 J4 J3 J6 J4 J1 JF1 FAN2 GND VCC 28V GND 28V GND LJB0304D SCB0300B LCR0305D XLR socket fan SDI0200B GTD L3100 fan 1412050023A 56V GND ...

Страница 18: ...tes LED aluminum substrate 5802010033A 2 LJB0304D LED driver board 5802030037A 1 LCR0305D Display board 5809210026B 1 L3100 101E11 102F11 103F11 SDI0200B XLR board 5802910008A 1 SKL0006B Switching power supply 1412050023A 1 EDS350 5628PN 350W EAGL Appendix 1 ...

Страница 19: ...GTD L3100 User Manual 18 Notes P N 1502011034A Time May 15th 2017 ...

Отзывы: