background image

 

GTD-L2008P User Manual 

15 

Cleaning and maintenance 

It is required that the fixture should be kept clean and well maintained to ensure its reliability. Its lifespan mainly depends 
on the working environment and proper operation. Should you have any questions, please consult a technical engineer of 
GTD Lighting.   

Notes 

Damage resulted from dust, smoke, oil or improper use is not covered by warranty.   

Warning 

Disconnect the fixture from AC power, and let it cool down for at least 15 minutes before opening the housing. Make sure 

to  use  a  soft  cloth  to  clean  the  optical  components,  and  be  careful,  as  the  coating  is  easily  scratched.  Do  not  use  any 

organic solvent such as alcohol to clean the reflector mirror, dichroic color filters or housing of the fixture. 

 

If the lens is cracked or otherwise damaged, replace it immediately.   

 

If the LED lamp becomes damaged or deformed in any way it must be replaced. 

 

If the light from the LED lamp appears dim, this normally indicates that it is reaching the end of its life span and 

should be changed at once. Aged LED lamps run to the extremity of their life might explode. 

 

If  fixture  does  not  function,  check  the  fuse  on  the  power  socket  of  the  fixture.  Replace  the  fuse  of  the  same 
specification if it is blown. 

 

The fixture is equipped with thermal-protection device that will switch off the LED lamp in case of overheating. If 
this happens, please check that the fans are not blocked, and clean them if they are dirty. Check whether the fans 

are operational. If not, call a qualified technician. Troubleshoot and correct the problem before switching on the 
fixture again. Any maintenance work should only be carried out by qualified technicians. 

 

 

 

 

 

 

 

 

 

Содержание GTD-L2008P

Страница 1: ...LED Effect Light GTD L2008P User s Manual Guangzhou GTD Culture Technology Group Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Страница 2: ...ies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within ...

Страница 3: ... Accessories 5 Product introduction 6 Installation 6 Device installation 6 Power Control connection 7 Power connection 7 Control connection 7 Testing 8 Control panel 8 Menu structure 9 DMX protocol 10 Technical specification 13 Cleaning and maintenance 15 Troubleshooting 16 System wiring diagram 17 Spare parts list 17 Appendix 1 17 ...

Страница 4: ...G Fire hazard It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Before ap...

Страница 5: ...h as cracks or scratches must be replaced to ensure performance of the fixture Disconnect the fixture from power before changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be u...

Страница 6: ...ories Remove the foam from the top put away the accessories and then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the ...

Страница 7: ...rew 3 Cast aluminm cover 4 Bracket 5 DMX input 6 Power indicator 7 DMX output 8 Power input 9 MENU UP DOWN ENTER buttons 10 DMX indicator 11 Power output Installation Device installation This fixture can be installed on stage or mounted in any directions On the wall On the ground ...

Страница 8: ... fixture is correctly grounded and the electrical installation conforms to all relevant Standards Codes of Practice for Safe Electrical Work Control connection The fixture has 5 pin XLR connectors for DMX data input and output 3 pin optional as shown below Connection between the console and fixture and between fixtures must be made with 2 core screened DMX signal cable Maximum connecting distance ...

Страница 9: ...of the fixture Press UP or DOWN to view or select the function menu Press ENTER to choose a function and enter into corresponding sub menu Each menu represents a specific function of the fixture Press ENTER to select the specific function and save the changes or enter into the submenu then press UP or DOWN to change the value of the selected function increase or decrease Press MENU to return to th...

Страница 10: ...lue D ON ON OFF Turn on or off the Backlight time function EDDY ON OFF Inverted Display SET RDMX ON OFF Allow the console to change the Address DEFA ON OFF Factory reset FANS AUTO HIGH LOW Setting the Fans status Save OFF 1 99M 15M Close the LED light when no signal Ver V1 0 V9 9 Software version STAT R xx xxx Manual control Edit SEPR AUTO IP01 IP10 Selecting the program that want to edit STEP S 0...

Страница 11: ...t 0 0 6 Blue 1 0 255 0 0 100 0 No light Full light 0 0 7 white 1 0 255 0 0 100 0 No light Full light 0 0 8 Red 2 0 255 0 0 100 0 No light Full light 0 0 9 Green 2 0 255 0 0 100 0 No light Full light 0 0 10 Blue 2 0 255 0 0 100 0 No light Full light 0 0 11 white 2 0 255 0 0 100 0 No light Full light 0 0 12 Red 3 0 255 0 0 100 0 No light Full light 0 0 13 Green 3 0 255 0 0 100 0 No light Full light ...

Страница 12: ...ght 0 0 34 Blue 8 0 255 0 0 100 0 No light Full light 0 0 35 white 8 0 255 0 0 100 0 No light Full light 0 0 36 7 Rainbow Function 0 9 0 0 3 5 No function 0 0 10 39 3 9 15 3 Rainbow scene 1 40 71 15 7 27 8 Rainbow scene 2 72 103 28 2 40 4 Rainbow scene 3 104 135 40 8 52 9 Rainbow scene 4 136 167 53 3 65 5 Rainbow scene 5 168 199 65 9 78 0 Rainbow scene 6 200 231 78 4 90 6 Rainbow scene 7 232 255 9...

Страница 13: ... 8 33 3 Flash effect 14 86 90 33 7 35 3 Flash effect 15 91 95 35 7 37 3 Flash effect 16 96 100 37 6 39 2 Flash effect 17 101 105 39 6 41 2 Flash effect 18 106 110 41 6 43 1 Flash effect 19 111 115 43 5 45 1 Flash effect 20 116 120 45 5 47 1 Flash effect 21 121 125 47 5 49 0 Flash effect 22 126 130 49 4 51 0 Flash effect 23 131 135 51 4 52 9 Flash effect 24 136 140 53 3 54 9 Flash effect 25 141 145...

Страница 14: ...nels DMX 40 11 Protocol DMX 512 Display 4 x 8 segment display Physical Installation Weight 5 5kg 12 lbs IP rating IP65 Material Aluminum steel Minimum distance to combustible materials 1 64ft 0 5m Minimum distance to illuminated surfaces 3 28ft 1m Dynamic effects Strobe 1 25Hz synchronized pulse effects Dimmer 0 100 16 bit electronic linear dimming 600Hz 1200Hz smooth or snap dimmer mode optional ...

Страница 15: ...GTD L2008P User Manual 14 Certification and Safety EMC EN 55103 1 2009 EN 55103 2 2009 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2013 Safety EN 60598 2 17 1989 A2 1991 Photometric ...

Страница 16: ...sing of the fixture If the lens is cracked or otherwise damaged replace it immediately If the LED lamp becomes damaged or deformed in any way it must be replaced If the light from the LED lamp appears dim this normally indicates that it is reaching the end of its life span and should be changed at once Aged LED lamps run to the extremity of their life might explode If fixture does not function che...

Страница 17: ... of the fixture Choose the channel mode in Channel setting Channel Mode of the fixture as required by the user Malfunctioning of DMX cannon input output connectors No input output voltage to the main control board of the fixture Troubleshooting the DMX XLR signal plate of the fixture replace the main control board of the fixture LED lamp off There is no signal output to the main control board PWM ...

Страница 18: ...5802010059A 1 LJB0523C Display board 5809210077B 1 L2008P 101K10 SDI0516D 1 Program control board 5809211003A 1 L2008P 201K01 202K01 203K01 204K01 LCR0542B 4CPU Appendix 1 L N GE 12V 12V POWER JC1 JF1 JF2 JE1 JE2 SDI0516D JC JIN1 LJB0523C JC LCR0542B J2 JE2 JE1 J1 5 J2 5 J1 ESS170 12PN GTD L2008P water proof socket water proof socket Signal line 1 Signal line 2 ...

Страница 19: ...GTD L2008P User Manual 18 Notes P N XXXXXXXXX Time August 30th 2017 ...

Отзывы: