13. Warning and error messages
Press
ENTER
key to do firmware upgrade
Firmware upgrade
Under AC power supply, you can choose the power
allocation mode, intelligent allocation or average
allocation.
First priority: intelligent allocation.
Dynamic Mode: average allocation.
Power Allocation
It will show the Error information with a beep sound when operation error.
1. {" BATTERY CONNECT ERROR "}
Interruption of battery and output end, or
the charger wire has not been connected
well when charging or discharging
2.{" INPUT VOLTAGE FLUCTUATION "}
Input voltage fluctuation range over 1V,
please check input power to ensure input
voltage fluctuation range not exceeds the
normal allowable range.
3.{"BATTERY VOL ERR CELL CONNECT"}
unit battery voltage error, please check the
battery voltage one by one.
4.{" TEMP OVER ERR "}
The internal temperature of the unit goes
too high, you need to cooling down the unit
5.{" SHORT CIRCUIT ERROR"}
Short circuit, you need to check charge
circuit and related equipment.
6.{"CAP OUT "}
Over the charger’s capacity protection set
value, you need to check and reset the
capacity protection value.
7.{"INPUT VOLTAGE ERROR"}
Input voltage error, you need to check the
input power to make sure the input power
correct.
8.{"REVERSE PLOARITY"}
Battery output polarity connection wrong,
you need to reverse connected battery
polarity.
9.{"SAFETY TIME OUT!"}
You need to reset the safety charge time.