31
Indirect Water Heaters
Exclusive, patented innovation.
Height to T
op of Coil Connection
Height to T
op of Potable W
ater Connection
Height to T
op of Heater
Diameter
Shipping W
eight
AB
C
D
Model
in. (cm)
in. (cm)
in. (cm)
in. (cm)
lb. (kg)
JW5-30IT
35 (89)
34 (86)
32 (81)
22 (56)
130 (59)
JW5-40IT
45.5 (116)
44 (112)
42.5
(108)
22 (56)
160 (73)
JW5-75IT
56 (142)
54 (137)
53 (135)
26 (66)
270 (122)
*
When the boiler input exceeds 100,000 BTU/H and if the unit has a factor
y supplied
T&P valve,
it must be replaced with one ra
ted for tha
t input.
Head Loss: 3GPM-9" W
.C.,
5GPM - 24" W
.C.,
8GPM - 62" W
.C.
CAP
ACITY & PERFORMANCE
First Hr
. Rating
Continuous
Capacity
Boiler Output
90
0
F/50
0
C Rise
Flow
Coil Length
Model
USG (Litres)
BTU
USG (Litres)
USG (Litres)
in. (cm)
JW5-30IT
30 (110)
40,000
70 (265)
69 (261)
29 (74)
60,000
98 (371)
104 (394)
80,000
125 (473)
139 (526)
100,000
152 (575)
173 (655)
JW5-40IT
40 (150)
40,000
84 (318)
69 (261)
39.5 (100)
60,000
111 (420)
104 (394)
80,000
138 (522)
139 (526)
100,000
165 (625)
173 (655)
JW5-75IT
75 (300)
40,000
120 (454)
70 (265)
47.25 (120)
60,000
148 (560)
105 (397)
80,000
175 (662)
140 (530)
100,000
201 (761)
174 (659)
120,000*
229 (867)
209 (791)
ROUGH-IN DIMENSIONS
GSW_ProdCatalog_Inside.qxd 3/7/08 1:51 PM Page 35
Содержание 6G-75-3NC
Страница 1: ......
Страница 7: ...Residential ...
Страница 8: ......
Страница 43: ...Commercial ...
Страница 44: ......
Страница 65: ...Tankless ...
Страница 66: ......
Страница 71: ...Appendices ...
Страница 72: ......
Страница 86: ......