![GST SMR-IP10-D Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/gst/smr-ip10-d/smr-ip10-d_installation-and-operation-manual_2275656040.webp)
No
Item
LED Indication
Description
1
Checking
Alarm_1900
→
GREEN LED Blinking
Power
→
GREEN LED Blinking
1900_Isolation Re-Check
2
Checking
Alarm_800
→
GREEN LED Blinking
Power
→
GREEN LED Blinking
800_Isolation Re-Check
3
Alarm
Alarm_800 & Alarm_1900
→
LED OFF
Power
→
RED LED ON
Low Input Voltage (DC Feeding to DAU)
4
Alarm
Alarm_800 & Alarm_1900
→
RED LED ON
Power
→
RED LED Blinking
Link Fail between DAU and SAU
5
Alarm
Alarm_1900
→
RED LED Blinking
Power
→
RED LED Blinking
Lack of Isolation between DAU and SAU @1900
6
Alarm
Alarm_800
→
RED LED Blinking
Power
→
RED LED Blinking
Lack of Isolation between DAU and SAU @800
7
Alarm
Alarm_1900
→
RED LED ON
Power
→
RED LED Blinking
1900 PLL Fail
8
Alarm
Alarm_800
→
RED LED ON
Power
→
RED LED Blinking
800 PLL Fail
9
Alarm
Alarm_1900
→
RED LED ON
Power
→
RED LED ON
1900 Shut Down
10
Alarm
Alarm_800
→
RED LED ON
Power
→
RED LED ON
800 Shut Down
LED Display
40
Technician’s Installation & Operation Guide
LED Display: operating and alarm status
Содержание SMR-IP10-D
Страница 19: ...Cable Length 50m 164 ft 19 Technician s Installation Operation Guide Link cable Installation Guideline...
Страница 46: ...46 Technician s Installation Operation Guide IP Address 192 168 1 1 Log In...
Страница 47: ...Easy Setup 47 Technician s Installation Operation Guide...
Страница 48: ...Professional Setup 48 Technician s Installation Operation Guide...