Pending FCC Appproval 

Model 5103A 

System Settings and User Notes 

 

 

 

 

The World Leader in  

Subsurface Imaging™ 

 

 

 

 

Geophysical Survey Systems, Inc. 

Tel 603.893.1109 • Fax 603.889.3984 

[email protected] 

www.geophysical.com 

 

June, 2008

Содержание 5103A

Страница 1: ...CC Appproval Model 5103A System Settings and User Notes The World Leader in Subsurface Imaging Geophysical Survey Systems Inc Tel 603 893 1109 Fax 603 889 3984 sales geophysical com www geophysical com June 2008 ...

Страница 2: ...d including the right of reproduction in whole or in part in any form Published by Geophysical Survey Systems Inc 12 Industrial Way Salem New Hampshire 03079 Printed in the United States GSSI RADAN and SIR are registered trademarks of Geophysical Survey Systems Inc ...

Страница 3: ... A PARTICULAR PURPOSE GSSI s obligation is limited to repairing or replacing parts or equipment which are returned to GSSI transportation and insurance pre paid without alteration or further damage and which in GSSI s judgment were defective or became defective during normal use GSSI ASSUMES NO LIABILITY FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR INJURIES CAUSED BY PROP...

Страница 4: ...detailed operational areas to the FCC Office of Engineering and Technology who shall coordinate this information with the Federal Government through the National Telecommunications and Information Administration The information provided by the UWB operator shall include the name address and other pertinent contact information of the user the desired geographical area of operation and the FCC ID nu...

Страница 5: ...on FCC requires that all users of GPR who purchased antennas after July 15th 2002 register their equipment and areas of operation If you have purchased any of the antennas listed in question 6 after July 15th 2002 you must fill out this form and fax or mail to the FCC Failure to do this is a violation of Federal law 1 Date 2 Company name 3 Address 4 Contact Information contact name and phone numbe...

Страница 6: ...5100 5101 1 0 GHz QF75101 4108F 1 0 GHz QF74108F HandyScan 1 0 GHz QF7HANDYSCAN 3101D 900 MHz QF73101D 5103 400 MHz QF75103 5103A 400 MHz QF75103A 50400 400 MHz QF750400 TerraVision 400 MHz QF7TERRAVISION 5104 270 MHz QF75104 5106 200 MHz QF75106 7 Receipt Date Of Equipment Fax this form to the FCC at 202 418 1944 Or Mail to Frequency Coordination Branch OET Federal Communications Commission 445 1...

Страница 7: ...m 100 MHz to 100 GHz the radiation protection guide is 10 mW cm milliwatt per square centimeter as averaged over any possible 0 1 hour period Emissions data using GPR SIR System 10 SIR 2 SIR 3 SIR 4 SIR 8 SIR 20 SIR 2000 and SIR 3000 at the standard Pulse Repetition Frequency of 100 KHz with the antenna Models listed and levels of Electromagnetic Radiation are specified herein Following is the ave...

Страница 8: ...Geophysical Survey Systems Inc Model 5103A Antenna System Settings and User Notes This page intentionally left blank MN30 265 Rev ...

Страница 9: ...ical Survey Systems Inc Model 5103A Antenna System Settings and User Notes Table Of Contents Model 5103A Antenna 1 System Setup Standard Settings 1 Signal Position 2 Gain Check 2 Specifications 2 MN30 265 Rev ...

Страница 10: ...Geophysical Survey Systems Inc Model 5103A Antenna System Settings and User Notes MN30 265 Rev ...

Страница 11: ... dielectric constant of 9 Setup Mode Manual System Run Mode Survey Wheel recommended or Continuous Range 50 ns Number of Gain Points 5 Vertical Low Pass Filter 800 MHz Vertical High Pass Filter 100 MHz Samples per Scan 512 Bits per Sample 16 Scans per Second Set to 120 recommended Deep Profiling For approximately 5 m 16 ft with a dielectric of 9 Setup Mode Manual System Run Mode Survey Wheel recom...

Страница 12: ...pling pulse time zero is recorded the user should place the signal Position servo in the manual mode The signal should then be moved down in the time range window until the entire surface pulse is visible and there is some dead time or flat trace visible above the direct coupling pulse in the time range window Gain Check The surface pulse should be about 2 3 the width of the screen If it is greate...