- 40 -
PADA 5100
—>
At Cascading the SID-Range (page 21) of the "upstream" cassettes
must be set to "0xxx"
, so that the static SID assignment of the
"downstream" cassette works.
Table for "static" SID assignment at station filter setting "cascaded"
16 Bit SID
Input
1
00
2
00
3
00
4
00
5
00
Input SID
SID at the outpu
t
11
11
21
31
41
51
12
16
26
36
46
56
21
12
22
32
42
52
22
17
27
37
47
57
31
13
23
33
43
53
32
18
28
38
48
58
41
14
24
34
44
54
42
19
29
39
49
59
51
15
25
35
45
55
52
10
20
30
40
50
If more than one services
are present at one input of
the "upstream" cassettes
(cassettes 1…5 of the exam-
ple), in the "downstream"
cassette (cassette 6 of the
example) the SIDs will be
assigned "statically" accord-
ing to the table beside.
According to this table up
to 6 services per input (cas-
settes 1…5) can be proc-
essed.
Example:
If at input 2 of cassette 2 two services are present, SID 22 is assigned to the
2nd service at the output of cassette 2 (according to the "dynamic" scheme at
page 30). This
SID 22
is present at
input 3
of cassette 6.
According to the table beside the SID is transformed in cassette 6 to
SID 37
.
From the 3rd service at one input of the cassettes 1…5 on the SIDs will be
transformed "dynamically" in cassette 6 (serial SIDs – up to 255 – will be as-
signed to input SIDs not included in the table).