proCedures
After installing the head-end station, upgrading accessories or installing cas-
settes it is necessary to tighten all cable connections, cable terminals and cover
screws in order to maintain compliance with current EMC regulations securely.
• Securely tighten the cable connections using an
appropriate open-ended
spanner.
• Measure the output levels of the other cassettes and tune them to a uniform
output level using the appropriate level controls or software dependent on
the head-end station used. Please regard the assembly instructions of the
respective head-end station.
—> In order to prevent interference within the head-end station and the
cable system, the output levels of the digital cassettes must be set
lower by 8 dB compared to analogue cassettes.
• Mount the front cover (s. assembly instructions of the head-end station).