background image

 

 

- 19 - 

HDE 166

 

Q

uantit y

 

of

 

data

 

paCkets

 

f

orward

 

error

 

CorreCtion

 / t

r ansmission

 

Channel

 

 

In this menu you set the quantity of the data packets to be transmitted, the for-
ward error correction FEC and the transmission channel. If the forward error 
correction is used the data to be transmitted is encoded in a redundant way 
so that the addressee can correct transmission errors.

IP  1

…4

  7        off

PKTS/FEC

   

 

Defining the quantity of data packets

 

•  Press the   button to select the data packet digit.

 

•  Using the 

 buttons define the quantity of MPEG data packets in one IP 

data packet ("

1

" … "

7

").

 

Setting the forward error correction 

 

•  Press the   button to select the forward error correction.

—>  In position "

off

" the forward error correction (FEC) is switched off.

 

•  Using the 

 buttons set the desired value of the FEC ("

off", "10/9

" … 

"

20/19

").

 

Setting the transmission channel 

 

•  Press the   button to select"

Annex…

".

 

•  Use the 

 buttons to set the desired transmission channel ("

AnnexA

" / 

"

AnnexB

").

 

•  Press the   button.

—>  The "Transport stream ID and ORGNET ID" –  "

TS/ONID

"  submenu  is 

activated.

Содержание HDE 166

Страница 1: ...Assembly Instruction HDE 166 ...

Страница 2: ...2 Selecting the module channel strip 13 Ethernet parameters 13 IP address of the cassette 14 Address range subnet mask 14 Address of the gateway 15 UDP port 15 IP output signal 16 Output IP address 17 Destination MAC address 17 Transmission protocol Port number 18 Quantity of data packets 19 Forward error correction Transmission channel 19 Transport stream ID and ORGNET ID 20 Input parameter 20 Da...

Страница 3: ...tight and the covers are screwed on securely No liability is accepted for damage caused by faulty connections or inap propriate handling of the device Check the head end station according to the safety instructions listed in their assembly instruction Take precautions to prevent static discharge when working on the device Electronic devices should never be disposed of in the household rubbish In a...

Страница 4: ...s the guidelines and standards for CE labelling page 27 Unless otherwise noted all values are specified as typical CVBS Video Inputs Standard DIN EN 50049 1 Input level 1 Vpp Input impedance 75 Ω Frequency range 20 Hz 5 MHz Audio Inputs Standard DIN EN 50049 1 Input level 500 mVrms Input impedance 10 kΩ Frequency range 20 Hz 15 kHz MPEG2 Encoder Transport stream MPEG2 ISO IEC 13818 1 Video data st...

Страница 5: ...iption The 4xMPEG2 encoder module converts four analogue audio and video sig nals into MPEG2 data streams transport streams and emits them via the Ethernet output The bit rates audio and video are adjustable L R FBAS CVBS Audio Eingang Audio input Cinch Video Eingang Video input Cinch ENCODER AV 1 µP TPS MODUL L R FBAS CVBS Audio Eingang Audio input Cinch Video Eingang Video input Cinch AV 2 L R F...

Страница 6: ...encoder module and the head end station can be updated using a PC and the software BE Flash via the 9 pin D SUB socket on the head end station You can find the current operating software for the head end station and the encoder mod ule the software BE Flash and the current assembly instructions on the web site www mygss eu The encoder module is designed exclusively for use in the STC 160 head end ...

Страница 7: ... housing of the head end station in accordance with the assembly instructions for the STC 160 Open the locking device A in the direction of the green arrow A Insert the Encoder module in grooves B of an open slot with contact strip on the board at the rear wall of the housing and gently slide it into the head end station until it makes contact with the board on the rear wall After installing the E...

Страница 8: ... current EMC regulations it is necessary to connect the lines leading in and out of the head end station using cable terminals When mounting the module in a head end station which is installed in a 19 cabinet make sure the connections leading in and out for the 19 cabinet are made using cable terminals Tighten the nuts on the cable terminals until the teeth on the lock washer have pen etrated the ...

Страница 9: ... be set are underlined With the button select the channel strip other modules You can use the button to select the following menu items LAN settings Hardware IP address IP mask sub net mask IP gateway UDP Port LAN output settings MPTS SPTS Output IP address es MAC address of destination device only at unicast connection Transmission protocol Port number Quantity of data packets Forward error corre...

Страница 10: ... submenu set values and triggers actions saves all entries 1 shows the enter position M S Bx 2 static ETHERNET DHCP SPTS 1 SPTS 2 SPTS 3 SPTS 4 nur wenn IP Adresse außerhalb des Multicastbereichs liegt Unicastverbindung only if IP address is out of multicast range Unicast connection Bx 2 192 168 IP ADDR 0 128 Bx 2 255 255 IP MASK 255 0 Bx 2 192 168 IP GATEWAY 0 1 Bx 2 60000 UDP PORT Bx 2 MPTS IP O...

Страница 11: ...o only PAL N 3 58 MHz 16 9 sharp soft Joint Dual Mono L 192 256 320 384 1 255 11 11 Programmnummer ist bereits belegt Programme number is already in use M STORE Bx 2 S STORE MEMORY A Einstellung speichern store factory defaults S M M M A Bx 2 Defaults FACTORY Bx 2 STORE FACTORY S Werkeinstellung aufrufen invoke factory defaults S UDP RTP 1 7 10 09 AnnexB 20 19 AnnexB 1234 IP 1 4 7 off PKTS FEC IP ...

Страница 12: ...l NOT be saved You will be returned to Selecting the module channel strip Switch on the head end station The display shows SETUP BE160 and the software version of the head end station e g V 10 The output level of the output collector can be adjusted in the SETUP menu see STC 160 assembly instructions Ein On SETUP V 10 BE160 M CANCEL STORE Bx 2 S STORE MEMORY A A Einstellung speichern store factory...

Страница 13: ...rnet parameters In this menu you specify whether the Ethernet parameters for the prospectively intended control of the cassette are entered automatically by a connected server DHCP or manually via the menu static To assign the cassette uniquely each IPTV cassette must be allocated its own IP address If no Ethernet settings should be done press button The IP output signal OUTPUT main menu is activa...

Страница 14: ... the corresponding menu The star in the display means that the data is provided by a DHCP server Bx 2 192 168 IP ADDR 0 128 Use the buttons to select the digits of the IP address displayed to be set and use to set the desired IP address Press the button The Address range subnet mask IP MASK submenu is activated Address range subnet mask In this menu you define the address range for the cassettes c...

Страница 15: ...e desired IP address Press the button The UDP port UDP PORT submenu is activated UDP port The UDP port setting is required if the cassette needs to be reached externally for remote maintenance Bx 2 60000 UDP PORT Use the buttons to select the digit of the port number displayed to be set and use to set the desired port number 0 65535 Press the button Return to the main menu Ethernet parameters Pres...

Страница 16: ...ne press button The Input parameter INPUT main menu is activated page 20 Bx 2 MPTS IP OUT Using the buttons select the desired kind of data stream MPTS or SPTS 1 4 If MPTS is selected the IP output settings must only be passed one time because all input signals are included in one data stream If SPTS is selected the IP output settings must be passed four times SPTS 1 SPTS 4 because for each input ...

Страница 17: ...multicast range is set below the menu for entering the MAC ad dress of the receiver is displayed Press the buttons to select the digit of the IP address to be set Using the buttons set the desired IP address Press the button If the IP address is within the multicast range The Transmission protocol Port number MODE PORT sub menu is activated page 18 If the IP address is out of the multicast range T...

Страница 18: ...sion protocol UDP The User Datagram Protocol is for the connectionless without handshake transmission of data to a certain application The port number of the service is also sent which the data should obtain RTP The Real time Transport Protocol is for continuously trans mitting multimedia data streams in an IP network Unlike UDP the header is transmitted which makes the data transmission more ro b...

Страница 19: ...e quantity of data packets Press the button to select the data packet digit Using the buttons define the quantity of MPEG data packets in one IP data packet 1 7 Setting the forward error correction Press the button to select the forward error correction In position off the forward error correction FEC is switched off Using the buttons set the desired value of the FEC off 10 9 20 19 Setting the tra...

Страница 20: ... to the main menu IP output signal If necessary perform the IP output settings for additional SPTS data streams When you exit the menu note that the desired kind of data stream MPTS or SPTS 1 SPTS 4 is be set Press the button The Input parameter INPUT main menu is activated Input parameter In this menu you select the input you would like to set the input parameters in the submenus AV 1 AV 4 Bx 2 A...

Страница 21: ...ATE Use the buttons to set the data rate of the video signal 2 0 15 0 Mbit sec If only audio signals are to be encoded set the data rate to Audio only In setting Off the input is switched off Press the button The TV standard NORM submenu is activated TV standard In this menu the TV standard of the input signal is to be set PAL BG 4 43 MHz or PAL N 3 58 MHz AV 1 4 PAL BG NORM 4 43 MHz Use the butto...

Страница 22: ... the buttons to set the desired sharpness Press the button The Audio signal type and bit rate Audio submenu is activated Audio signal type and bit rate In this menu you set the signal type and the bit rate the audio signal is to be encoded AV 1 4 Stereo AUDIO 256 kbps Use the buttons to set the signal type Stereo Joint Stereo sub jectively improved stereo impression Dual Channel dual channel sound...

Страница 23: ...In this menu you can adapt the volume of this audio input AV 1 4 VOLUME 0 dB Use the buttons to set the desired volume 11dB 11dB Press the button The Programme number PRG NUM submenu is activated Programme number SID Service ID In this menu you can set the Service ID of the input AV 1 4 00001 PRG NUM Use the buttons to set the desired Service ID 1 255 A behind the Service ID indicates that this ID...

Страница 24: ...eter Use the buttons to select the 2nd AV input and carry out its settings analogous to that of the 1st AV input or Press the button The Factory reset FACTORY Defaults main menu is activated Factory reset In this menu you can reset all settings to the factory defaults M M M Bx 2 Defaults FACTORY Bx 2 STORE FACTORY S S Press the button The factory defaults are invoked FACTORY STORE By pressing the ...

Страница 25: ...ing settings M CANCEL STORE Bx 2 S STORE MEMORY S All programmed data is saved by pressing the button The settings are saved Return to Selecting the module channel strip page 13 By pressing the button you will be returned to the menu item Se lecting the module channel strip without saving the programmed data ...

Страница 26: ...pgrading accessories or installing mod ules it is necessary to tighten all cable connections cable terminals and cover screws in order to maintain compliance with current EMC regulations securely Mount the base plate and the front cover see STC 160 assembly instruc tions ...

Страница 27: ...ms GmbH Beuthener Straße 43 D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 www gss de en info gss de Service Phone 49 0 911 703 2221 Fax 49 0 911 703 2326 service gss de Alterations reserved Technical data E O E by GSS GmbH V3 17022017 ...

Отзывы: