background image

- 3 -

- 3 -

   

4 Adjustments

4.1  Removing the housing cover

 • 

Remove 

screw 

B

 (Fig. 1) and take off the housing cover.

4.2  Position of the adjustment elements

 (Fig. 2)

C

 – Attenuation control (output level) 

F

 –  Return channel confi guration 

D

 – Line equalization control 

G

 –  Attenuation 0/10 dB

E

 – Attenuation control (input/return channel)   

  (output/return channel)

4.3 Level 

adjustments

 • 

Use the attenuation control 

C

 (output level) and 

E

 (level of the return channel) to

 

 

set the necessary HF level, Fig. 2, (factory setting – full to right = 0 dB).

 

•  Put the attenuation jumper 

G

 in vertical (“off = 0 dB”) or horizontal direction

 

 

(“on = 10 dB”).

 

 • 

Use 

control 

D

, Fig. 2, to set the line equalization 

 

 

(factory setting – full to right = 0 dB).

4.4 Confi guring the return channel

 

•  Position the jumpers 

F

 (Fig. 2) according to Fig. 3 (factory setting – active).

 

HF output /

return channel

input

HF input /

return channel

output

158 mm

HF output /

return channel

input

HF input /

return channel

output

158 mm

!

 

-20 dB

0 dB

0 dB

-20 dB

0 dB

18dB

#

$

"

!

 

-20 dB

0 dB

0 dB

-20 dB

0 dB

18dB

#

$

"

Fig. 1: Assembly / Connections

Fig. 1: Assembly / Connections

Fig. 2: Positions of the adjustment elements

Fig. 2: Positions of the adjustment elements

”on = 10 dB”

”off = 0 dB”

”on = 10 dB”

”off = 0 dB”

"active"

"passive"

"locked"

"active"

"passive"

"locked"

Fig. 3: Positioning the jumpers

Fig. 3: Positioning the jumpers

Содержание AR 5218

Страница 1: ... D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 Email info gss tv Internet http www gss tv Assembly Instructions Assembly Instructions English AR 5218 AR 5298 Distribution Amplifiers A A CLASS CLASS KLASSE KLASSE Grundig SAT SystEms ...

Страница 2: ...pter if the amplifier is disconnected from the mains Dispose of the product after use as electronic waste in compliance with the ap plicable disposal regulations 2 Technical description The interactive multimedia capability distribution amplifiers built into a die cast housing are for supplying small building units and CATV house networks Beside the adjustable amplifier they contain the diplex fil...

Страница 3: ...G in vertical off 0 dB or horizontal direction on 10 dB Use control D Fig 2 to set the line equalization factory setting full to right 0 dB 4 4 Configuring the return channel Position the jumpers F Fig 2 according to Fig 3 factory setting active HF output return channel input HF input return channel output 158 mm HF output return channel input HF input return channel output 158 mm 20 dB 0 dB 0 dB ...

Страница 4: ... 5 65 85 862 5 65 Gain Attenuation Line equalization Assigned value attenuation dB dB dB dB 21 0 20 0 18 19 0 20 0 10 30 0 20 0 18 24 0 20 0 10 Noise figure dB 6 6 Return loss 40 MHz 1 5 MHz oktave min Cat C dB 14 17 14 17 Impedance Ω 75 Output level IMA 60 dB IMA 2 acc EN 50083 3 IMA 3 acc EN 50083 3 IMA 3 acc EN 50083 5 CSO Cenelec 42 Channel 862 MHz CTB Cenelec 42 Channel 862 MHz Maximum operat...

Отзывы: