Содержание CWT5020

Страница 1: ......

Страница 2: ...eally realizes wireless alarm control and remote managements and solves the limitation of wired data transmission in telephone and wired network Perfect structure convenient installation easy operation with wireless control keyboard are designed for the idea of people oriented which will make you feel easy and comfortable while use this system People is center technology is first is our company s ...

Страница 3: ...tings 12 4 2 3 Alarm voice call 12 4 2 4 Power fail alarm 12 4 2 5 Alarm delay time 12 4 2 6 Arm delay time 12 4 2 7 Wired in types 13 4 2 8 Timer mode 13 4 2 9 Restore factory 13 4 2 10 Erase RF sensor 13 4 2 11 RF decoder 13 4 2 12 GSM band setup 13 V VIEW STATUS OF HOST 14 5 1 View status of Wired inputs 14 5 2 View the alarm records 14 5 3 View the alarm records 14 5 4 View Timers 14 5 5 View ...

Страница 4: ...sarm 16 7 3 Sound alarm enable disable 16 7 4 Emergency alarm 16 VIII LCD ICON DISCRIPTION 17 IX QUICK OPERATION COMMAND BY KEYBOARD 18 X SMS OPERATION COMMAND 18 XI ENCODE THE WIRELESS DETECTORS AND REMOTE CONTROLLER 20 ...

Страница 5: ... Power off Host it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal screening by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified...

Страница 6: ...d send SMS Alert and dial to the pre set cellphone when any sensor activated 4 Equips with 4 Wired Zones NC NO and Zone Name is editable 5 Equips with 8 Wireless Zones Normal Bypass mode and Zone Name is editable 3 24 Hour zones for Panic button smoke and gas leakage sensor 6 Supports 10 alarm telephones and 20 Alarm Records for owner review 7 Supports 6 timing points 4 pre set timing points for c...

Страница 7: ...Adaptor X1 PC Programmer Tool CD X1 User Manual X1 2 3 Specifications of Mainframe of the GSM Alarm System Rated Voltage 12VDC 1 5A Working temperature 10 60 Storage temperature 20 60 Relative humidity 10 90 No condensation Work frequency GSM900 1800Mhz or 850 900 1800 1900MHz Communication protocol GSM PHASE 2 2 include data service Wireless sensor receiving frequency 433 0 5MHz Wired Zones 4 Wir...

Страница 8: ...8 III The host Installation 3 1 Alarm Host s section figure Speaker menu button LCD display Keyboard Power switch SIMcard socket USB ...

Страница 9: ...PIN3 Wired sensor input 3 PIN4 Output relay positive electrode Relate voltage 3A 250VAC PIN4 Wired sensor input 2 PIN5 PIN5 Wired sensor input 1 PIN6 Output relay negative electrode Relate voltage 3A 250VAC PIN6 Wired sensor input 0 Tips The Microphone is the same as computer microphone you can use the computer microphone to it Tips Wired sensor input can connect Temperature sensor Water leakage s...

Страница 10: ...LCD display turns on and shows the status of arm disarm GSM signal etc IV Setup steps 4 1 Quick Guide Login system 1 Press OK button input password The initial password is 000000 must be numbers Set the mobile phone number 2 After enter Main menu please select Setup and select Store phones press OK to add phones by keyboard while delete phones you can press UP button to delete phone numbers You ca...

Страница 11: ...word 4 please enter Setup menu and select Password press OK to set password by keyboard Main menu 0 view 1 Operation 2 Setup Setup 0 24 hours zone 1 Zone settings 2 Store phones 3 Time date Time date 00 00 00 00 00 Main menu 0 view 1 Operation 2 Setup Setup 4 Password 5 Alarm voice call 6 Power fail alarm 7 Alarm delay tim Password ...

Страница 12: ... AC power failure and recoverd need the host send SMS to alarm or not 4 2 5 Alarm delay time please enter Setup menu and select Alarm delay time press OK to set Alarm delay time in the time host will not send SMS when alarm In this way you have a enough time to set in disarm mode when you enter the monitor area 4 2 6 Arm delay time please enter Setup menu and select Arm delay time press OK to set ...

Страница 13: ...Setup menu and select Restore factory press OK to Reset the host 4 2 10 Erase RF sensor please enter Setup menu and select Erase RF sensor press OK to remove all of wireless sensors 4 2 11 RF decoder please enter Setup menu and select RF decoder press OK to select EV1527 or PT2262 64 default is PT2262 the host support two kinds of wireless sensor that base on EV1527 or PT2262 64 wirless IC But onl...

Страница 14: ... press OK to view the timers you have set 5 5 View Wired in sms please enter View menu and select Wired in sms press OK to view the sms alert contents of the wired zones that you have set 5 6 View RF zone sms please enter View menu and select RF zone sms press OK to view the sms alert contents of the RF zones that you have set Wired inputs Wired in0 Normal Wired in1 Normal Wired in2 Normal Wired i...

Страница 15: ...ress OK to set the siren enable or disable 6 4 Learn RF sensor please enter Operation menu and select Learn RF sensor press OK to start after select yes you can trigger a wireless sensor then you will hear di di sound for learn successflly 6 5 Call and Hang up call please enter Operation menu and select Call press OK and keyed in phone numbers and press ok to dial if you need to hang up the call y...

Страница 16: ...ode and the is on 7 3 Sound alarm enable disable Press on remote controller the host will make di sound the LCD display is twinkling and the is on host is in at house mode and the siren alarm is enabled and is on next press button agina the host will make di di di di sound the LCD display is twinkling and the is on the siren alarm is diabled 7 4 Emergency alarm When an emergency alarm occurs press...

Страница 17: ...ption Host is in arm mode Host is in diarm mode Host is in at house arm mode The siren alarm is enabled The siren alarm is diabled GSM signal Learn RF sensor Power supply by external AC power Power supply by internal battery ...

Страница 18: ...alarm 999 X SMS Operation command Operations Command Arm BF Disarm CF Query system status dayrp CS n phone numbers n 0 9 Set ten mobile phone numbers for host Example Set 1388888888 as the first mobile phone number for host Send sms CS01388888888 Query all phone numbers CS CS n n 0 9 Delete phone numbers Example Delete CS9 mobile phone number ...

Страница 19: ...3 Set 4 Wired Zones alarm sms Example Set temperature alarm as the alarm sms of wired input 0 Send sms S00temperature alarm S n message n 04 07 Set 4 Wired Zones recover sms input type must be LEVEL Example Set temperature recover as the recover sms of wired input 0 Send sms S04temperature alarm Set emergency alarm sms S08 message S n message n 09 20 Change 11 Wireless Zones alarm sms Example Set ...

Страница 20: ...Zone01 Bypass 1 0 1 0 PIR Zone02 Bypass 0 1 1 0 Temperature Zone03 Bypass 1 1 1 0 Smoke Zone04 Default is 24 hour zone Bypass 0 1 0 1 Gas Zone05 Default is 24 hour zone Bypass 1 1 0 1 Water Zone06 Bypass 0 0 1 1 Glass Zone07 Bypass 1 0 1 1 Glass external Zone08 Bypass 0 1 1 1 PIR external Zone09 Working 1 1 1 1 Door external Zone10 Working 1 1 0 0 Smoke external Zone11 Default is 24 hour zone Work...