- 12 -
alarm phone number
phone number on the alarm panel for SMS messages.
Press alarm panel query key of your keyboard, then blinking status LED on
and then press 41#, the alarm panel LCD show 13812345678 means the
first set of SMS message is 13812345678
Syntax:
4+
【
1-6
】
+
【
#
】
Query password
Used to query the current password of the alarm panel , Press alarm panel
query key of your keyboard, then blinking status LED on and then press
50#, the alarm panel LCD show 1234. alarm panel your current password
is 1234 . Press # to clear the screen, press * then press # to exit the query
mode.
Syntax:
50 +
【
#
】
Query the time for delay
arm
Query delay time for arm (00-99) Seconds
Press alarm panel query key of your keyboard, then blinking status LED on
and then press 51#, the alarm panel LCD show 00 mean time for delay is 0
second.
Syntax:
51 +
【
#
】
Query delay time for
alarming
To query the alarm delay time (00-99) Seconds
Press alarm panel query key of your keyboard, then blinking status LED on
and then press press 52#, the alarm panel LCD show 00 mean time for
delay is 0 second.
Syntax:
52+
【
#
】
Query siren sounding
time for alarming
To query the siren sounding time (00-20) minutes when the alarming.
Press alarm panel query key of your keyboard, then blinking status LED on
and then press 53#, the alarm panel LCD show 01 mean time for delay is 1
minute.
Syntax:
53+
【
#
】
Query remote control
audible confirmation
For query the setting of remote control 00-99 for the audible confirmation
to command.
Press alarm panel query key of your keyboard, then blinking status LED on
and then press 5501#, the alarm panel LCD show ON means remote
control 1 is set to sound upon receipt of command.
Syntax:
55+
【
00-99
】
+
【
#
】
Query the scheduled
time for arm and disarm
Used to query first to fourth set of scheduled time for arm and disarm.
Press alarm panel query key of your keyboard, then blinking status LED on
and then press 5701# to query the first of scheduled arm and disarm, the
alarm panel LCD show ” Mon, Tue, 22-00 07-00” means schedule set as
Monday and Tuesday 22:00 pm arm and 07:00 am disarm.
Syntax:
57+
【
01
-
04
】
+
【
#
】
Query type wireless
defense zone
For query the zone types of 00-99.
The alarm panel LCD show the name of type of zone, detail about zone
types can be referred to another section of manual, the word “ON” or
“OFF” next to the zone type represents whether siren will sound upon
alarming.
Syntax:
60+
【
00
-
99
】
+
【
#
】
Query the type of wired
zones
For query the zone type of 51-54.
Example: Press alarm panel query key of your keyboard, then blinking
status LED on and then press 6151# to query 51 zone alarm type, show
NO means short-circuit to alarm while show NC means open circuit to
alarm.
Syntax:
61+
【
51
-
54
】
+
【
#
】
Query
alarm
panel
arm/disarm records
The system can save up to the most recent 72 disarmed records.
Press alarm panel query key of your keyboard, then blinking status LED on
and then press 9901#, press 8 to scroll up and 0 to scroll down for records.
Syntax:
Содержание Burglar