background image

How to Programme the SMS

You can now change the alarm message for inputs 1 & 2 to your own choosing.

To change the message send the text command as follows.

NOTE

 - Your message should read a message of your choosing up to 19 characters long.

#

 MESS1

=

YOUR MESSAGE

#

 

The default message is  (Input 1)

#

MESS2

=

YOUR MESSAGE

#

 

The default message is  (Input 2)

This will change the message to ‘YOUR MESSAGE’

Telephone Call Alerts

The Auto Dialler can be programmed to send you a call after each text alarm has been
sent.

You will receive approximately three ring tones. The unit will then hang up automatically
avoiding any call charges being incurred.

To set call alerts to ON please send the text message

#

CALL

=

ON

#

The unit will reply back “CALL ON”

To disarm the call alerts please send the text message.

#

CALL

=

OFF

#

If the call function has been set to ON you will receive a text message and shortly after a
phone call.

How to Use the GSM Auto Dialler

The Auto Dialler has two inputs.

Input 1 = Terminal 1 Connection. 

(Negatively Triggered)  Pulled to Ground

Input 2 = Terminal 2 Connection. 

(Negatively Triggered)  Pulled to Ground

When the inputs are triggered the 

GREEN 

ready LED will flash 6 times to indicate that a

trigger has been received and it will send a text and/or call to the saved user numbers.

Both Input 1 and input 2 can be triggered independently.

The Auto Dialler will reset automatically when the triggered input is released.

Page 5

www.gsm-activate.co.uk

 - 01273462380 - [email protected]

Содержание ECO DIALLER V4

Страница 1: ...PAGE 1 MODEL ECO DIALLER V4 2G 3G GSM DIALLER MINI eCO RANGE ...

Страница 2: ... enclosure ensuring it is perfectly weathered for outside installation and has passed testing in high heats and below freezing conditions Specification GSM Frequency Quadband Freq 850 900 1800 1900 3G model 2100mhz Power Supply Voltage 9 24 volts DC 1 Amp Min Current used in standby mode 60mA Max IP65 Rated Enclosure for outside installation 2 Inputs Negative triggered 5 Users Micro Simcard No lan...

Страница 3: ... you can text the unit to see how much signal strength the Auto Dialler is receiving Please text the command SIGNAL The eco Auto Dialler will perform a test on the signal strength and report with a score of between 0 to 30 We strongly recommend that you place the unit where you will a signal score of at least 10 You will find anything less that this will make the unit unreliable If you have a 3G D...

Страница 4: ...2 3 07345678912 To save for contact no 3 4 07345678912 To save for contact no 4 5 07345678912 To save for contact no 5 If you wish to cancel a number please follow this example Example hash 1 2 3 4 or 5 equals DELETE hash 1 DELETE Then send this to the simcard within the unit IMPORTANT PLEASE READ Please send one message at a time and wait for the Auto Dialler to respond by sending the text acknow...

Страница 5: ...all alerts to ON please send the text message CALL ON The unit will reply back CALL ON To disarm the call alerts please send the text message CALL OFF If the call function has been set to ON you will receive a text message and shortly after a phone call How to Use the GSM Auto Dialler The Auto Dialler has two inputs Input 1 Terminal 1 Connection Negatively Triggered Pulled to Ground Input 2 Termin...

Страница 6: ...panel instructions INPUT 1 2 As you can see in the circuit diagram above the input can be activated by pulling the input 1 2 to ground The input can also be used with a variety of sensors and switches to trigger it and send out a text and call alert www gsm activate co uk 01273462380 sales gsm activate co uk ...

Страница 7: ...vate co uk Alternatively you can email our technical support team at technical gsm activate co uk and we will do our best to reply within 24 hours Monday to Friday 21 09 21 GD Page 7 Typical Application of this Product Pumping stations tanks oil or water levels Security alarm system applications Supervision and monitoring alarm systems Automatic monitoring system Vending machines security protecti...

Отзывы: