background image

Page 2 of 4

Model:

SR 1212

Unit 2, 110 Station Road, Seven Hills ,NSW,  2147, Australia

12Volt 12Amp 

Solar Regulator

Operating Instructions

Please read these instructions before use

SR12-R1

Operational Parameters 

                                                                                            SR1212-1                                   SR1212-2

Maximum Current at Bulk Charge

12A

12A

Input Operating Voltage Range

15V to 25Volts

15V to 25Volts

Maximum Charge Voltage for Flooded Cell (LEAD 
ACID)

14.6Volts

14.6Volts

Maximum Charge Voltage for Lithium

-

14.4Volts

Maximum Charge Voltage for AGM/GEL

-

14.2Volts

Float Voltage 

13.5Volts

13.5Volts

Lithium Maintenance Charge

-

13.2V

Standby Current

0.01A

0.01A

Maximum Operating Temperature

70°C

70°C

Automatic Derating Above 45°C

0.5A/°C

0.5A/°C

Typical Efficiency

98%

98%

LVD On/Off

-

On : <11V  OFF : <12.5V

Status LED

-

YES

Dimensions 

81mm(L) x 37mm(W) x 22mm(H)

81mm(L) x 37mm(W) x 22mm(H)

Weight

50g

70g

• Use only PV systems with open circuit voltage below 25v and 250W rated peak power.
• Install the unit away from flammable liquids or gases.
• Use wires suitable for at least 15A, but if wire runs are over 3m then larger wires are recommended to limit voltage 

  drop and losses.

• A battery fuse ( BF ) is always required and must be located as close as possible to the positive battery terminal and
  before any other connection. The fuse ratings will depend on the wire size and load but typically a 15A fuse 

  is envisaged.

• Before connecting always check battery and PV panel polarity & Do not short PV or Load with Battery connected!
• Always check that the correct chemistry setting is used and that the voltage levels are suitable for your specific 

  battery. 

• Only use Lithium batteries with a suitable BMS.
• This appliance is not meant for use by young children.
• During the charging process on a vented battery do not use a naked flame near a battery which may ignite and explode. 
• Never smoke or light cigarettes near a battery.
• Do not place tools on top of battery or allow tools to fall on to the battery.
• Always wear eye protection near a charging battery.
• Ensure a “well” ventilated area is used when testing or charging batteries. 
• Ensure ventilation is adequate and venting holes are not obstructed. 
• If skin or clothing comes into contact with acid, flush the area(s) with water immediately and seek medical attention if 

  necessary.

Important installation and safety notes

Содержание SR 1212

Страница 1: ... and weather proof Featuring Operating from panels that are peak rated to 250W Very high efficiency typically over 98 Low night time discharge current below 10mA Selectable multichemistry For Sealed Lead Acid Flooded Cell Lead Acid and Lithium LiFePO4 chemistries Note This feature is only available on SR1212 2 only The SR1212 1 fixed for Flooded Cell Lead Acid Simple Status LED Indication SR1212 2...

Страница 2: ...res are recommended to limit voltage drop and losses A battery fuse BF is always required and must be located as close as possible to the positive battery terminal and before any other connection The fuse ratings will depend on the wire size and load but typically a 15A fuse is envisaged Before connecting always check battery and PV panel polarity Do not short PV or Load with Battery connected Alw...

Страница 3: ... LED Indicators Guide Fig 1 BATTERY SETUP Choose a cable size suitable for your situation Low Voltage Disconnect LVD The LVD function of the unit utilized on the GREEN wire is designed to protect the battery from over discharge by dis connecting the negative load wire GREEN when the battery voltage drops below 11V for over 2 Seconds It reconnects automatically when a new charge cycle starts Not Av...

Страница 4: ...e customer is also entitled to have the products repaired or replaced if the products fail to be of acceptable quality and the failure does not amount to a major failure GSL Electronics GSL warrants that its products will under normal use and service be free of defects in material and workmanship for a period of two 2 years from the date of the original purchase by the customer as marked on the cu...

Отзывы: