background image

Page 1 of 4

Model:

SR 1212

Unit 2, 110 Station Road, Seven Hills ,NSW,  2147, Australia

12Volt 12Amp 

Solar Regulator

Operating Instructions

Please read these instructions before use

SR12-R1

Operation Guide

Thank You for purchasing another quality GSL Product.
The SR 1212 is a Negative Switched PWM Solar Panel Regulator which is feature rich and powerful for it’s size due to it’s 
microcontroller based design with the added bonus of polymer encapsulation making it water and weather proof. 

Featuring:

• Operating from panels that are peak rated to 250W
• Very high efficiency, typically over 98%
• Low night time discharge current, below 10mA.  
• Selectable multichemistry. For Sealed Lead Acid , Flooded Cell Lead Acid and Lithium (LiFePO4) chemistries. (Note: This 
  feature is only available on SR1212-2 only. The SR1212-1 fixed for Flooded Cell Lead Acid)  
• Simple Status LED Indication (SR1212-2 model only) 
• High operating temperatures - Safely work up to 70°C.
• High reliablity due to dual over temperature protection. 
• Built in Low Voltage Disconnect (LVD) (SR1212-2 model only) 
• Advanced 3 stage automatic PWM charging algorithm

SR 1212 

Note: Coin for size 

          reference only.

Содержание SR 1212

Страница 1: ... and weather proof Featuring Operating from panels that are peak rated to 250W Very high efficiency typically over 98 Low night time discharge current below 10mA Selectable multichemistry For Sealed Lead Acid Flooded Cell Lead Acid and Lithium LiFePO4 chemistries Note This feature is only available on SR1212 2 only The SR1212 1 fixed for Flooded Cell Lead Acid Simple Status LED Indication SR1212 2...

Страница 2: ...res are recommended to limit voltage drop and losses A battery fuse BF is always required and must be located as close as possible to the positive battery terminal and before any other connection The fuse ratings will depend on the wire size and load but typically a 15A fuse is envisaged Before connecting always check battery and PV panel polarity Do not short PV or Load with Battery connected Alw...

Страница 3: ... LED Indicators Guide Fig 1 BATTERY SETUP Choose a cable size suitable for your situation Low Voltage Disconnect LVD The LVD function of the unit utilized on the GREEN wire is designed to protect the battery from over discharge by dis connecting the negative load wire GREEN when the battery voltage drops below 11V for over 2 Seconds It reconnects automatically when a new charge cycle starts Not Av...

Страница 4: ...e customer is also entitled to have the products repaired or replaced if the products fail to be of acceptable quality and the failure does not amount to a major failure GSL Electronics GSL warrants that its products will under normal use and service be free of defects in material and workmanship for a period of two 2 years from the date of the original purchase by the customer as marked on the cu...

Отзывы: