1700W Solar Battery Charger 

Maximum Power Point Tracker

Operating Instructions

Please read these instructions before use

Unit 2, 110 Station Road, Seven Hills ,NSW,  2147, Australia

Model:

MPPT30-2

Q: What sort of batteries should I use?

   

1.

 A deep cycle battery is a must due to the cyclical nature of the solar system with a 

      recommended battery capacity of at least 180AH. 

   

2. 

A larger battery will not only give longer run time during low light but also will be able to avoid 

      available PV power being unstored such as when battery reaches the float stage.

Q: How do PV temperatures affects charge current?

    Temperature increase brings down the PVs maximum power point voltage reducing the MPPTs 

    current gain available. In principle at 25C it is possible to achieve 30% gain but at 40C, a more 

    realistic average temperature, about 20% is still available. 

Q: What sorts of loads can I power with the MPPT30?

   

1. 

The maximum bulk charge current with the MPPT30 on a 12V battery and 400W panel is 

      approximately 30A, so you can expect about 100AH per day which means a 100W load for 

      about 10 hours daily. 

 

  2. 

Following the same reasoning with a 24V 800W panel the MPPT30 will supply a daily load of 

      200W for about 10 hours.

 

  3.

 Following the same reasoning with a 48V 1600W panel the MPPT30 will supply a daily load of 

      400W for about 10 hours.

MPPT30-2-R8

Q: Is interference possible? and If so what do I do?

 

    GSL’s MPPTs produce far less interference than conventional solar regulator during 
   

the absorption and float stages, that is during most of its operating time, and its 

    designed to comply with local and international EMI standards however some 
   

interference is still possible. If interference occurs first try and reorient the aerial or move 

    the sensitive equipment away from the MPPT wires. Ensure the MPPT chassis is grounded.  
   

Grounding a battery terminal may also help and finally you can try adding ferrite clamps. 

Warranty Conditions:

 Our products come with guarantees that cannot be excluded under the Australian Consumer Law.

The customer is entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable 

loss or damage.

The customer is also entitled to have the products repaired or replaced if the products fail to be of acceptable quality and the failure does not 

amount to a major failure

.

GSL Electronics (GSL) warrants that its products will, under normal use and service, be free of defects in material and workmanship for a 
period of two (2) years from the date of the original purchase by the customer as marked on the customer’s original invoice. Please refer to our 
website for full warranty and return information which can be found at http://www.gsl.com.au/faq.html

Содержание MPPT30-2

Страница 1: ...08 and 09 and the Greentech Consensus Awards 09 A simple compact and low cost alternative Ideal for charging batteries with the new low cost and high efficiency grid type panels The MPPT 30 2 is designed to automatically charge 12V 24V and 48V sealed and vented lead acid batteries from silicon based PV panels such as monocrystalline polycrystalline and thin film It has a built in Load Low Voltage ...

Страница 2: ...DC fuse would do The lowest Maximum Power Point system voltages are 18V for 12V batteries 36V for 24V batteries and 72V for 48V batteries to ensure full power MPPT30 2 Specifications Efficiency typical 96 Input voltage 16V to 95V Output voltage Float 13 5V 27V 54V Absorption Vented LA Batteries 14 5V 29V 58V Sealed LA Batteries 14 2V 28 4V 56 8V Output power 1700W 30A MAX Quiescent current 0 05A T...

Страница 3: ... protected from overdischarge Wiring With Low Voltage Disconnect Figure 2 This option protects the battery from overdischarge by disconnecting the load The LVD option disconnects the load when the battery voltage drops below 0 85 of nominal voltage to protect the battery from damage The load reconnects when the battery voltage exceeds 0 95 of nominal voltage This feature will not trigger during sh...

Страница 4: ...ritical loads are loads which can be disconnected to ensure maximum on time for critical loads as well as to extend the life expectancy and reliability of the system The non critical load can be set up as LVD or Dawn to Dusk loads Wiring with MCM option Connecting the optional MCM to the MPPT will allow various system parameter display output voltage and alarm settings and enable the programmable ...

Страница 5: ...42 32 63 48 84 64 42 32 84 64 Grid Connect Panel size no cells in grid 1x18 Cell Grid 10 8 1x48 Cell Grid 28 23 2x48 Cell Grid 56 46 3x48 Cell Grid 84 69 1x52 Cell Grid 31 25 2x52 Cell Grid 62 50 3x52 Cell Grid 93 75 1x54 Cell Grid 32 26 2x54 Cell Grid 64 52 3x54 Cell Grid 96 78 1x60 Cell Grid 36 29 2x60 Cell Grid 72 58 1x72 Cell Grid 44 36 2x72 Cell Grid 88 72 1x96cgsp 65 55 For optimal performan...

Страница 6: ...e 1 Ensure all the MPPT wires are disconnected 2 Remove 7 front panel screws and the front panel and slide out cover see Figure 4 3 Locate connector J4 see Figure 4 4 Shift link on J4 to vented position see Figure 5 5 Slide back cover and fit in front panel carefully insuring led fits properly into housing and screw back the 7 mounting screws The above procedure can be repeated to turn back to sea...

Страница 7: ...to standard solar regulators 1 Suitable for new lower cost high efficiency grid type panels since the GSL MPPT can efficiently charge the batteries from relatively high voltage say 12V batteries from 36V MPP panels 2 Less interference and more accurate voltages during absorption and float Q What happens at low PV currents The MPPT will outperform the conventional regulator above 3 of nominal panel...

Страница 8: ...600W panel the MPPT30 will supply a daily load of 400W for about 10 hours MPPT30 2 R8 Q Is interference possible and If so what do I do GSL s MPPTs produce far less interference than conventional solar regulator during the absorption and float stages that is during most of its operating time and its designed to comply with local and international EMI standards however some interference is still po...

Отзывы: