background image

 

Product Name:

 

Telecom Battery Box                                  Product Model:

 

GSL-P48100ESA1                              Rev No.: A0 

DATE: Aug 30, 2021 

 

   

voltage DC power supply, and take good personal protection measures; 

(2)

 

Keep away from children; 

(3)

 

Avoid touching exposed metal parts before touching the battery; 

(4)

 

In order to prevent the accumulation of static electricity, the maintenance personnel should 
release the static electricity from the human body before operating the battery; 

(5)

 

Do not place tools or metal parts on the top of the battery; 

(6)

 

Do not step on or sit on the battery; 

(7)

 

Do not short circuit the positive and negative electrodes of the battery directly; 

(8)

 

It is forbidden to change the battery without authorization; 

(9)

 

It is forbidden to cover the battery during charging and discharging; 

(10)

 

It is forbidden to charge or discharge the battery module directly without BMS or other charging 
and discharging protection measures. 

2.1.3.

 

Responding to Emergencies 

(1)  Electrolyte Leakage 

In case of electrolyte leakage, immediately follow the following instructions; 

Inhalation: evacuate the contaminated area and seek medical advice immediately; 

Eye contact: Rinse eyes with running water for 15 minutes and seek medical advice immediately; 

Skin  contact:  wash  the  affected  area  thoroughly  with  soap  and  water  and  seek  medical  advice 
immediately; 

Ingestion: cause vomiting and seek medical advice immediately. 

(2)  Battery Soaking 

If the battery is immersed in water, do not continue to use. 

(3)  Battery Damage 

If the battery is damaged, please contact us directly. 

2.2.

 

Purpose 

GSL-P48100ESA1 battery box can be used for communication base station power supply or home energy 
storage and other similar scenarios. 

2.3.

 

Appearance 

 

Содержание GSL-P48100ESA1

Страница 1: ...User Manual Product Name Telecom Battery Box Product Model GSL P48100ESA1 Date 30 08 2021 Approve Review Proofread Compile ...

Страница 2: ...Product Name Telecom Battery Box Product Model GSL P48100ESA1 Rev No A0 Revised Sheet ED Amendment Reviser Revision Date A0 The new release David 2021 08 03 ...

Страница 3: ...rements 1 2 Product Description 2 2 1 Notes 2 2 2 Purpose 3 2 3 Appearance 3 2 4 Structure 4 2 5 Electric 5 2 6 Communication Function 6 3 Installation 7 3 1 Tools and Safety Devices 7 3 2 Structure installation 7 3 3 Electrical installation 8 4 Operating 11 4 1 Power on 11 4 2 Shutdown 11 5 Maintenance 11 6 Troubleshooting 11 7 Interpretation of Abbreviated Words 11 8 Product Warranty 12 ...

Страница 4: ...tions Amount Standard Optional 1 Battery box GSL P48100ESA1 1 Standard 2 Positive power cable 1m 25mm red 1 Optional 3 Negative power cable 1m 25mm black 1 Optional 4 Communication network cable 1m blue 1 Optional 5 User manual 1 Standard 1 2 Transport Requirement During transportation the battery packing box must be placed properly and avoid strong vibration impact and heavy pressure 1 3 Storage ...

Страница 5: ... injury or slight or moderate damage to equipment or property Do not short circuit Do not disconnect or disassemble by non professionals Do not place near flammable materials Do not place the battery near fire Please read the product manual before installation and use Keep out of reach of children animals or insects Recyclable Do not dispose of this product with domestic waste 2 1 2 Operational Sa...

Страница 6: ... and discharging 10 It is forbidden to charge or discharge the battery module directly without BMS or other charging and discharging protection measures 2 1 3 Responding to Emergencies 1 Electrolyte Leakage In case of electrolyte leakage immediately follow the following instructions Inhalation evacuate the contaminated area and seek medical advice immediately Eye contact Rinse eyes with running wa...

Страница 7: ...Serial Number Name Label Function Description 1 SOC indicator 2 Warning indicator ALM Alarm in case of battery failure 3 Operation indicator RUN Flashing during battery charging and discharging 4 Dial switch ADD Address setting for parallel connection of batteries 5 Debugging port CONSOLE Connect the computer 6 Communication port CAN RS485 CAN Communication with inverter RS485 Battery pack cascade...

Страница 8: ...ure below for the electrical schematic diagram of battery box Figure 5 electrical schematic diagram of the product Please refer to the table below for the electrical performance parameters of residential battery box Table 4 product electrical parameters S N Key items Specifications 1 Type of battery LFP 2 Cell Connection 1P15S 3 Rated voltage 48V 25 2 4 Rated energy 4 8kWh 5 Standard charging curr...

Страница 9: ...ity 5 95 RH 23 Weight About 40kg 24 Dimensions W D H 442mm 479mm 128mm 25 Installation location Indoor 2 6 Communication Function RS232 Communication port RS232 interface communicate with PC or other intelligent terminals PIN Signal 3 BMS TX 4 BMS RX 5 RS232_GND 1 2 6 NC RS485 Communication port The BMS shall be equipped with RS485 communication interface to communicate with FSU FSU and BMS commun...

Страница 10: ...l 4 CAN H 5 CAN L 8 GND 3 Installation 3 1 Tools and Safety Protection Appliance The following tools are required to install this product Wrench Electric screw driver Insulated gloves Goggles Safety shoes When installing moving and placing batteries always follow the instructions in the manual otherwise there may be safety hazards 3 2 Structure installation GSL P48100ESA1 telecom battery box suppo...

Страница 11: ...ng installation diagram Figure 7 installation fix method When installing fix the mounting ears on both sides of the front panel of the battery box to the bracket or other box with M6 screws 3 3 Electrical installation The GSL P48100ESA1 telecom battery box can be used alone or multiple systems can be used in parallel ...

Страница 12: ...nd the negative poles are connected in sequence The communication line is connected from the CAN RS485 of the first battery to the CAN RS485 of the second battery and the CAN RS485 of the second battery is connected to the CAN RS485 of the third battery and so on can connect up to 31 batteries The DIP switch on the panel needs to set up DIP configuration address Figure 8 electrical installation di...

Страница 13: ...xth bit of the other battery boxes does not need to be dialed 2 OFF ON OFF OFF OFF 3 ON ON OFF OFF OFF 4 OFF OFF ON OFF OFF 5 ON OFF ON OFF OFF 6 OFF ON ON OFF OFF 7 ON ON ON OFF OFF 8 OFF OFF OFF ON OFF 9 ON OFF OFF ON OFF 10 OFF ON OFF ON OFF 11 ON ON OFF ON OFF 12 OFF OFF ON ON OFF 13 ON OFF ON ON OFF 14 OFF ON ON ON OFF 15 ON ON ON ON OFF 16 OFF OFF OFF OFF ON 17 ON OFF OFF OFF ON 18 OFF ON OF...

Страница 14: ... and all indicators on the panel flash once and turn off indicating that the shutdown is successful 5 Maintenance Battery maintenance must be performed by qualified authorized personnel If the battery has been stored continuously for more than three months it must be fully charged once Every three months check whether the connections of battery communication and power cables are loose 6 Troublesho...

Страница 15: ...seal opening the casing Transport damage Incorrect installation or commissioning Failure to observe the user manual quick installation instructions Incorrect usage or inappropriate operation Insufficient ventilation of the device Failure to observe the applicable safety regulations Force majeure Neither does it cover cosmetic defects which do not influence the energy production Warranty conditions...

Страница 16: ...d information in and send this page to factory when you need to apply warranty service support Warranty Card User Information Company User Name Address Telephone Email Project installation location Product Information Battery Model Serial No Invoice Number Purchase Date Dealer Commission date Fault Error Description ...