BMPPT250-1 Specifications 

Efficiency Typical

 95%

Panel Voltage 

14V to 58V

Output Voltage (24V) 

29V ± 1%

Output Voltage (48V))

58V ± 1%

Panel Power Max

250W

Quiescent Current

0.04A 

Thermal Protection

Multilevel type

Dimensions (mm)

35 X 75 X 142mm

Indications

LED display – battery OK / LOW

PATENT APPLIED FOR - 2010901565

Содержание BMPPT250-1

Страница 1: ...gy that won GSL Electronics the prestigious 2008 EDN Innovation award A simple compact low cost and highly efficient way to cycle charge 24V and 48V batteries from low voltage or parallel panels BMPPT250 1 Unit BMPPT250 1 Specifications Efficiency Typical 95 Panel Voltage 14V to 58V Output Voltage 24V 29V 1 Output Voltage 48V 58V 1 Panel Power Max 250W Quiescent Current 0 04A Thermal Protection Mu...

Страница 2: ...ded for systems where the batteries are unloaded for long periods of time Page 2 of 4 Model BMPPT250 1 250W Solar Charger Booster Maximum Power Point Tracker Operating Instructions Please read these instructions before use BMPPT250 1 R3 Unit 2 110 Station Road Seven Hills NSW 2147 Australia BMPPT250 1 General Information Green LED ON battery charging and all normal Green LED FLASHING battery volta...

Страница 3: ...attery voltage of your system The switch is located through the hole of the faceplate of the unit For safety reasons this should only be changed whilst the BMPPT has been disconnected from both the Panels and the Battery Preferably before installation We also suggest the switch be changed gently with a non conductive tool Always ensure that the Switch is set for the Correct Battery Type When looki...

Страница 4: ...e the system more tolerant to partial shading when compared to series panel connection Q What output can I expect from a 250 BMPPT The maximum bulk charge current with a 48V battery and 250W panel is approximately 5A so you can expect about 20AH per day which is close to 100W load for about 10 hours Q Why are BMPPT used mainly in high power systems Until now and despite their overwhelming advantag...

Отзывы: