6. Fill System Control Box
PNEG-696
TopDry Series 2000 Autoflow
21
Fill System Control Box
The fill system control box houses the motor starters for fill system #1, fill system #2 and the aeration fan.
Switches are located on the front of the fill system control box and an Emergency Stop switch is located
on the side of the control box.
Fill System #1
This switch is used to start and stop fill system #1 manually. The switch should be left in the “AUTO”
position for normal dryer operation. If the switch is placed in the “OFF” position fill system #1 will not start
and will stop if running. If the dryer control power is ON, fill system #1 can be activated by placing the
switch in the “ON” position. When placed in the “ON” position, fill system #1 will operate continuously.
Fill System #2
This switch is used to start and stop fill system #2 manually. The switch should be left in the “AUTO”
position for normal dryer operation. If the switch is placed in the “OFF” position fill system #2 will not start
and will stop if running. If the dryer control power is ON, fill system #2 can be activated by placing the
switch in the “ON” position. When placed in the “ON” position, fill system #2 will operate continuously.
Aeration Fan
This switch is used to start and stop the aeration fan manually. The switch should be left in the “AUTO”
position for normal dryer operation. If the switch is placed in the “OFF” position the aeration fan will not
start and will stop if running. If the dryer control power is ON, the aeration fan can be activated by
placing the switch in the “ON” position. When placed in the “ON” position, the aeration fan will
operate continuously.
Emergency Stop Switch
This switch will stop the dryer when pushed and should be used in case of emergency.