Humidistat-Thermostat

HI-LO TEMPERATURE CONTROL

5. If the unit does not reach desired temperature,

8. Significant changes in outside air temperature

may require readjustment of gas pressure.

Note: If temperature of lo-flame exceeds thermo-
stat settings (above normal outside temperatures)
unit will cycle from lo-flame to off. (Top Dry units will
shut down completely)

1. Remove mounting screws from the thermostat

housing and remove the housing from the bin
wall.

2. Carefully remove the back panel from the hous

ing.  (It may be necessary to cut caulking).

The Airstream Humi-

distat-  Thermostat

is mounted on the

lower right side of

the grain bin's

transition. This al-

lows for easy ser-

vice and opera-

tion.

OPERATION & SERVICE

1. Turn fan unit on and let it run 3 to 5 minutes to

equalize temperature under the bin.

2. Rotate the thermostat knob clockwise to

warmest position.

3. Open gas valves (including lo-fire valve) to

the heater and turn the heater on. Set heater
gaspressure to a moderately high setting. (5
to 10 PSI)

4. Monitor the thermometer on the thermostat

housing. When the thermostat comes up to
desired temperature, slowly turn the most at
knob counter-clockwise until heater cycles to
lo-flame.

GSI Thermostats are designed and built to withstand
the harsh conditions usually found in drying bins.
A yearly preventative maintenance inspection may
extend the life of your heating controls many years.

3. Blow out any dust or dirt that may have collected

inside the housing.

5. Replace the back panel and caulk the corners to

help seal the unit.

6. Reinstall the unit on the bin wall.

HUMIDISTAT-THERMOSTAT SERVICE

ALWAYS DISCONNECT

AND LOCK OUT POWER

BEFORE WORKING ON OR

AROUND HEATER

gradually increase the gas pressure until the tem-
perature rises to desired level.

6. Adjust the lo-fire valve so that the temperature

drops  until the unit cycles back to hi-flame.

7. Watch the unit run through several cycles and

make any final adjustments. (Note:  The unit
should cycle approximately two times per
minute. If not adjust gas pressure).

4. Inspect the wiring for any loose connections,

or rodent and insect damage.

Содержание PNEG-236

Страница 1: ...OWNER S MANUAL HUMIDISTAT THERMOSTAT PNEG 236 MODEL HF __ __ __ __...

Страница 2: ......

Страница 3: ...LoThermostat 7 Operation 8 Operation Service 9 Humidistat Thermostat Parts 10 Lo Temp Humidistat Thermostat Parts 11 Hi Lo Humidistat Thermostat Parts 12 Humidistat ThermostatWiring 13 Thermostat Wiri...

Страница 4: ...OOF WARNING OPERATION SAFETY Thank you for choosing a GSI product It is de signed to give excellent performance and service for many years The principal concern of The GSI Group Inc GSI is your safety...

Страница 5: ...te power is supplied to your unit Safety decals should be read and understood by all people in the grain handling area The bottom right decal should be present on the inside bin door cover of the two...

Страница 6: ...nsert sensing probes through bin wall and secure housing to wall using self drilling screws provided Be careful not to overtighten screws Damage to housing could result 5 Make wiring connections to he...

Страница 7: ...model 3 Apply rope caulk to sides and top of plastic 5 Connect the black and white wires to the ter minals marked bin hi limit 3rd and 4th terminal bottom left hand terminal strip on fan and heater s...

Страница 8: ...10 PSI 7 Watch the unit run through several cycles and makeanyfinaladjustments Note Theunitshould be on approximately 80 of the time If not adjust gas pressure 8 Significant changes in outside air tem...

Страница 9: ...gaspressure to a moderately high setting 5 to 10 PSI 4 Monitor the thermometer on the thermostat housing When the thermostat comes up to desired temperature slowly turn the most at knob counter clock...

Страница 10: ...HF 1434 HH 1435 HH 1436 HH 1970 HH 2089 HH 1442 HF 7108 HH 7032 HH 7029 HF 7110 Description 2 66 Plastic Housing 4 00 Plastic Housing Thermostat Humidistat Static Pressure Gauge 220 Degree Thermometer...

Страница 11: ...436 HH 1970 HH 2089 HH 1442 HF 7108 HH 7032 HF 7110 Key 1 1 2 3 4 5 6 7 8 9 10 11 12 Description 2 66 Plastic Housing 4 00 Plastic Housing Lo Temp Thermostat Humidistat Static Pressure Gauge 140 Degre...

Страница 12: ...Temp Thermostat Static Pressure Gauge 220 Degree Thermometer Screen Plug Plastic Knob Large Red Plastic Plug Heat Shrink Tube 1 2 Thermostat Cover Rubber Grommet Humidistat Cover Part Number HF 1431 H...

Страница 13: ...13 Humidistat Thermostat HUMIDISTAT THERMOSTAT WIRING...

Страница 14: ...14 Humidistat Thermostat THERMOSTAT WIRING...

Страница 15: ...15 Humidistat Thermostat HUMIDISTAT WIRING...

Страница 16: ...16 Humidistat Thermostat HI LO THERMOSTAT WIRING...

Страница 17: ...17 Humidistat Thermostat MOUNTING TEMPLATE...

Страница 18: ...______________________________________________________________________ ___________________________________________________________________________________________________ _____________________________...

Страница 19: ...Y PROBLEMS MODIFICATIONS TO THE PRODUCT NOT SPECIFICALLY COVERED BY THE CONTENTS OF THIS MANUAL WILL NULLIFY ANY PRODUCT WARRANTY THAT MIGHT HAVE BEEN OTHERWISE AVAILABLE THE FOREGOING WARRANTY SHALL...

Страница 20: ...1004 E Illinois St Assumption IL 62510 Phone 217 226 4421 Fax 217 226 4498 June 1998...

Отзывы: