![GSi PNEG-1707 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/gsi/pneg-1707/pneg-1707_operation-manual_2275001052.webp)
9. Drying Time Tables
52
PNEG-1707
TM-Series Tower Dryer
Drying Time Table……..Model 1012
Reference Setting Table for Corn -- Model 1012
Reference Setting Table for Wheat, Barley, Milo -- Model 1012
Divider Set for Maximum Heat Area
Divider Set for Minimum Heat Area
Moisture
170°F
% Unload Rate
190°F
% Unload Rate
210°F
% Unload Rate
170°F
% Unload Rate
190°F
% Unload Rate
210°F
% Unload Rate
In
Out
17%
15%
820
970
780
910
18%
15%
620
730
850
590
690
790
19%
15%
510
600
690
480
560
640
20%
15%
430
510
590
410
480
550
21%
15%
370
440
530
360
410
470
22%
15%
330
390
450
310
370
420
23%
15%
290
340
400
280
320
370
24%
15%
260
310
350
250
290
330
25%
15%
230
280
320
220
260
300
26%
15%
210
250
280
200
230
270
27%
15%
190
220
260
180
210
240
28%
15%
170
200
230
160
190
210
29%
15%
150
180
210
150
170
190
30%
15%
140
160
190
130
150
180
32%
15%
120
140
160
110
130
150
35%
15%
90
110
120
90
100
120
Divider Set for Maximum Heat Area
Divider Set for Minimum Heat Area
Moisture
140°F
% Unload Rate
150°F
% Unload Rate
160°F
% Unload Rate
140°F
% Unload Rate
150°F
% Unload Rate
160°F
% Unload Rate
In
Out
15%
13%
660
730
810
620
690
760
16%
13%
500
550
610
470
530
570
17%
13%
410
450
500
380
430
470
18%
13%
350
380
420
330
360
400
19%
13%
300
330
370
280
310
350
20%
13%
260
290
270
250
280
310
21%
13%
230
260
290
220
250
270
23%
13%
190
210
230
200
200
220
25%
13%
150
170
180
140
160
170
Содержание PNEG-1707
Страница 1: ...TM Series Tower Dryer Operation Manual PNEG 1707 Version 2 1 Date 09 22 20 PNEG 1707...
Страница 21: ...4 Dryer Installation PNEG 1707 TM Series Tower Dryer 21 Modular Base Layout Figure 4A...
Страница 22: ...4 Dryer Installation 22 PNEG 1707 TM Series Tower Dryer Central United States Foundation Plan Figure 4B...
Страница 23: ...4 Dryer Installation PNEG 1707 TM Series Tower Dryer 23 Northern United States Foundation Plan Figure 4C...