8. Troubleshooting
General GRA Sampler Troubleshooting
Symptom
Possible Cause
Corrective Action
Sample does not cycle in either
auto or manual modes
(Power light OFF).
Power switch OFF.
Turn power switch ON.
Circuit breaker is open.
Reset breaker.
Main fuse is blown.
Replace. (See Main Fuse
)
Faulty supply wiring.
Correct. Refer to certified electrical
schematic.
Defective power switch.
Replace switch.
Sample does not cycle in either
auto or manual modes
(Power light ON).
Faulty system wiring.
Correct. Refer to certified electrical
schematic.
No or low air pressure.
Turn air supply on and set regulator
to 80-100 PSI.
Defective control valve.
See Directional Solenoid Valve
Troubleshooting
Sampler timer T-1 digital display
does not illuminate but sampler
works in manual mode.
Defective auto/manual switch S-2.
Replace switch if line voltage is
absent across #1 and #2 on timer T-1.
Defective timer T-1.
Replace switch if line voltage is
absent across #1 and #2 on timer T-1.
Sample size too small or large.
Speed control valves set too low or too
high.
Adjust speed control valves. (See Speed
Control Valves
Sample cutter opening too small or large.
Replace. (See Sample Cutter Blade
Replacement
Sample interval timer or counter set too
high or low.
Adjust sample interval timer T-1 or counter
C-1. (See Digital Display Timer T-1
(Standard)
) or (See Digital
Display Counter C-1 (Optional)
)
Sampler leaks air or material
continuously out the sample
discharge.
Sample cutter seals torn or missing.
Replace. (See Sample Cutter Seals
Replacement
Sample cutter not stopping under the
dust seals.
Adjust torque hub. (See Drive Arm
Positioning and Torque Hub Tightening
)
Sampler installed on a positive
pressure line.
Remove pressure by venting
sampler or consult InterSystems.
Sample cutter worn.
Replace. (See Sample Cutter Blade
Replacement
Sampler sluggish
(Operates too slowly).
Inadequate air supply.
Increase line size or add surge tank.
Regulator set too low.
Reset. (See Air Filter/Pressure Regulator
)
Filter clogged.
Clean as outlined in Section. (See Draining
and Servicing the Filter
Airline from filter regulator blocked
or damaged.
Inspect and correct.
Cylinder seal leakage.
See Air Components Troubleshooting
Careless or accidental restoration of power can result in death or serious injury.
Make certain area is clear before removing lock outs.