GSi GRA Скачать руководство пользователя страница 4

4

PNEG-2174

 Sampler - Model GRA

1. Introduction

This manual covers the installation and operation for the Sampler GRA Model. This manual provides 
guidelines for installing the product. You must retain a qualified contractor to provide on-site expertise. 
INTERSYSTEMS IS NOT RESPONSIBLE FOR THE INSTALLATION OF THIS PRODUCT.

InterSystems reserves the right to improve its product whenever possible and practical to do so. We 
reserve the right to change, improve and modify products at any time without obligation to make changes, 
improvements and modifications on equipment sold previously.

General Safety Statements

1. The Sampler system is designed and manufactured with operator safety in mind. However, residual 

hazards remain due to the nature of material handling, and specific material hazards. Use extreme 
caution at all times.

2. Modifications to equipment may cause extremely dangerous situations that could result in damage 

to the equipment as well as serious injury or death. Never modify the equipment.

3. Intersystems recommends that you contact the local power company to have a representative survey 

the installation to ensure wiring is compatible with their system and adequate power is supplied to 
the unit.

4. Consult InterSystems before making any changes to the sampler or its operating environment. 

Careless changes could result in death or serious injury to people and reduce the performance and 
service life of the equipment.

5. Never perform any service on this equipment or any powered equipment until all power has been 

shut off and locked out so that it cannot be restored without the consent and knowledge of the person 
who interrupted power. Power includes electrical, fluid, mechanical or pneumatic energy.

6. Never perform any service on this equipment without utilizing the required PPE (Personal Protective 

Equipment). Refer to the MSDS (s) (Material Safety Data Sheet (s)), on all the products to which this 
equipment is in contact to determine what PPE is required.

Scope

The certified drawings list the non-standard components that have been incorporated into the equipment. 
InterSystems, Inc. normally stocks non-fabricated parts and non-custom OEM parts. Replacement parts 
for any other components, including fabricated parts and custom OEM components can be supplied 
upon request.

This equipment is to be operated only on the voltage designated on the certified 
electrical drawings. Fire or explosion may result, which can cause death, serious 
injury and extensive damage to equipment. Do not connect to voltages other than 
designated.

Compressed air can cause severe injury. Shut off and lock out compressed air 
source to the sampler and bleed off any and all present compressed air within the 
sampler pneumatics before attempting any service on this sampler.

Содержание GRA

Страница 1: ...Sampler Model GRA Installation and Operation Manual PNEG 2174 Version 1 0 Date 01 04 18 PNEG 2174...

Страница 2: ...Model GRA All information illustrations photos and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes at any...

Страница 3: ...17 Pre Installation Preparation 17 Location 17 General Mounting Guidelines 17 Material Sample Transport Lines 18 Controller Location 18 System Wiring 18 System Piping 19 Chapter 6 Operations and Adju...

Страница 4: ...s operating environment Careless changes could result in death or serious injury to people and reduce the performance and service life of the equipment 5 Never perform any service on this equipment or...

Страница 5: ...s utilized on this equipment Repair Kits The following chart lists repair kits and parts that are available from InterSystems These kits are offered as a more economical solution by rebuilding the def...

Страница 6: ...t stay out of the work area at all times Alterations must not be made to the equipment Alterations can produce dangerous situations resulting in SERIOUS INJURY or DEATH This equipment must be installe...

Страница 7: ...symbol indicates an imminently hazardous situation which if not avoided will result in serious injury or death This symbol indicates a potentially hazardous situation which if not avoided can result i...

Страница 8: ...0004 1 Follow Safety Instructions Carefully read all safety messages in this manual and safety signs on your machine Keep signs in good condition Replace missing or damaged safety signs Be sure new e...

Страница 9: ...following these safety precautions creates the risk of falling equipment which could crush personnel and cause serious injury or death ST 0047 1 Sharp Edge Hazard This product has sharp edges which ca...

Страница 10: ...0070 1 Flying Material and High Pressure Air Hazard Flying material and or high pressure air can cause severe eye injury or blindness Wear safety glasses around operating equipment ST 0071 1 Stay Clea...

Страница 11: ...ventilated area Dispose of paint and solvent properly Remove paint before welding or heating Avoid potentially toxic fumes and dust Hazardous fumes can be generated when paint is heated by welding so...

Страница 12: ...enance of the equipment To replace a damaged of missing decal contact us to receive a free replacement InterSystems 13330 I Street Omaha Nebraska 68137 Phone 402 330 1500 FAX 402 330 3350 Figure 3A GR...

Страница 13: ...3 IS526X4 IS Logo WARNING Moving parts can cut and crush Lockout energy source before inspection or service Reorder No EMC 3032 C Clarion Clarionsafety com WARNING Flying material can cause severe ey...

Страница 14: ...ion WARNING Avoid serious injury or death This machine MUST be locked out in accordance with current OSHA requirements before any maintenance or service is performed Reorder No EMC 402 34 16089 C Clar...

Страница 15: ...e flows through the sample cutter and out the discharge as it swings through the material flow The sample cutter when at rest is situated under one of two dust seals that seal the sample cutter The sa...

Страница 16: ...in two enclosure classifications a The NEMA 9 control with the rating of Class 2 Groups E F and G Division 1 and 2 b The NEMA 7 control with the rating of Class 1 Groups C and D Division 1 and 2 Class...

Страница 17: ...performance Additionally the sampler should be located where the product has a non turbulent flow pattern The sampler and associated equipment should be located for ease of access and maintenance The...

Страница 18: ...troller in a hazardous area 4 Most applications require that the sampler be in easy view of the controller System Wiring Refer to the certified electrical drawing s for specific wiring requirements Th...

Страница 19: ...on installations where the compressed air source is further than 200 from the sampler to prevent excessive drop in air pressure InterSystems recommends installing a shut off valve upstream of the fil...

Страница 20: ...on the sampler size and speed control valve settings The pneumatic system on the sampler consisting of the filter regulator directional control valve and air cylinder was pre plumbed and tested at the...

Страница 21: ...4 Control Panel Detail Refer to the certified electrical drawing s for dimensions on control panels with optional features Failure to observe all safety rules written and implied and those suggested b...

Страница 22: ...OP mode When the AUTO mode is selected the illuminated display resets to the value dialed in to the Three Digit Preset Immediately the timer begins timing down When the illuminated display reads all z...

Страница 23: ...its housing upside down If the timer is forced into the housing upside down damage will result Digital Display Counter C 1 Optional As arranged for use in this system the counter operates in the DOWN...

Страница 24: ...er turns on the sampling light to indicate a sample is being taken An approximate setting of 1 to 3 seconds is required to provide an indication that a sample is being taken Main Fuse This fuse locate...

Страница 25: ...esult controls cylinder operating speed in only one direction The speed controls were factory set but may need minor adjustment due to differences in air supplies Use the following guidelines when adj...

Страница 26: ...sure setting always approach the desired setting from a lower pressure When reducing from a higher setting to a lower setting first reduce to a pressure setting lower than desired and then adjust upwa...

Страница 27: ...ation of the warning signs Warning signs are an important part of any safety program replace any missing signs IMMEDIATELY Lubrication Airline Lubricator An airline lubricator is not required The cyli...

Страница 28: ...ocedures Sample Cutter Blade Replacement When following the instructions below refer to the applicable drawing of the sampler Reference the section drawings of the samplers on Pages 35 and 36 and the...

Страница 29: ...r seal brackets the sampler housing avoid dropping the assemblies inside the sampler 5 Wrap the new seals around the seal brackets and re install 6 Move the sample pelican to its home position on each...

Страница 30: ...k clevis in place by tightening the jam nut 4 Check the position of the drive arm on the shaft with the alignment of the sample pelican The air cylinder must remain parallel to the top of the housing...

Страница 31: ...Valves on Page 25 Sample cutter opening too small or large Replace See Sample Cutter Blade Replacement on Page 28 Sample interval timer or counter set too high or low Adjust sample interval timer T 1...

Страница 32: ...a junction of horizontal and vertical sections of an air line This problem is particularly prevalent when there is high ambient humidity and the equipment operates infrequently and intermittently as...

Страница 33: ...ontaminants in the air supply can lead to scored cylinder walls resulting in rapid seal wear If such is the case check to see if the filter is being drained frequently A different type of filter may b...

Страница 34: ...es out of Port 3 and or Cylinder Port 2 the valve seals are defective and must be replaced If there is a leakage out of the line from the cylinder the cylinder seals are defective and must be replaced...

Страница 35: ...PNEG 2174 Sampler Model GRA 35 9 Parts List Sampler Model GRA Parts List NOTE The parts pointed out on this page are listed on Pages 37and 38...

Страница 36: ...9 Parts List 36 PNEG 2174 Sampler Model GRA Sampler Model GRA Parts List Continued NOTE The parts pointed out on this page are listed on Pages 37and 38...

Страница 37: ...4058 24058 24047 Flange Bearing 1 15 511365 511365 511366 Drive Arm 1 16 511368 511368 511369 Torque Hub 1 17 35869 35869 36465 Pivot Pin 2 18 35868 35868 36640 Rod Clevis 1 19 34544 34544 36429 Eye B...

Страница 38: ...25175 304 Stainless Steel 22 Dust Seal 516796 516797 523092 Urethane Sheet 2 35073 35073 35073 Gum Rubber Tube A R 23 Dust Seal Bracket 2 511217 511218 511219 HRS for Urethane 511210 511211 511212 304...

Страница 39: ...ctory or other than by an Authorized Service Representative This warranty does not cover the replacement of parts inoperative because of wear occasioned by use the cost of replacing parts by a person...

Страница 40: ...efully followed in all cases Authorities having jurisdiction should be consulted before installations are made InterSystems 9575 N 109th Ave Omaha Nebraska 68142 Toll Free 800 228 1483 www gsiag com C...

Отзывы: