PNEG-1807CE
CE Compliant 16"-24" Bucket Elevator Platform and Ladder “X” Series
17
6. Tie Angles, Ladder Brackets and Safety Cages
Chapter 6: Tie Angles, Ladder Brackets and Safety Cages
Attach Tie Angle to Boot Trunking
1. On the NON-LADDER SIDE, attach tie angle to the trunking using 1/2" x 1" bolts.
a.
For 16" Boot Tie Angle:
With lip of tie angle up and outward, align tie angle so that it extends
beyond the trunking at each end.
Figure 6A 16" Boot Tie Angle
Ref #
Part #
Description
A
BECT1640FX
Type “X” Tie Angle
B
S-7935
12" x 1" Bolt
Down-leg
Up-leg
16" Boot Tie Angle