9. Install Hatch
72
PNEG-1807CE
CE Compliant 16"-24" Bucket Elevator Platform and Ladder “X” Series
Install Hatch (Continued)
7. Assemble pipe clamps (S-10139) to the magnet mount hatch bracket (HP1648LMM). Insert
3/8" x 3/4" carriage bolts through the magnet mount hatch bracket, 1/2" flat washer and pipe clamp.
Fasten with 3/8" nut.
8. Attach pipe clamp around intermediate handrail and fasten loosely with bolts. Open hatch plate and
slide clamp along handrail until it lines up with the magnets on the hatch plate. Tighten clamp to rail.
Figure 9E
Ref #
Part #
Description
J
HP1648LMM
Magnet Mount Hatch Bracket
K
S-10139
Pipe Clamp 1" O.D. 3/8" Holes with Screw
L
3/8" Nut
M
1/2" Flat Washer
N
3/8" x 3/4" Carriage Bolt
Hatch Deck Door - Clamps