8. 4.00" Corrugation Farm Commercial Hopper Tank (FCHT) 7-9 Rings
108
PNEG-1451
Ladder, Safety Cage and Platform for Hopper Tanks
Location of Field Drilled Holes for Base/Access Door Ladder
Starter Brackets
Before the starter brackets can be installed, two (2) 3/8" holes must be drilled. The holes must be located
4" below and directly in line with the top horizontal seam holes located in the 3
rd
ring from the bottom (B)
of the tank. The first hole, required for the right hand starter bracket, must be located 9-3/8" from the center
of the left hand base platform mounting angle (A) to the center of the hole. The second hole, required for
the left hand bracket, must be located 18-3/4" from the center of the first hole. When located correctly, the
holes will be centered between the two (2) sets of mounting angles.
for the proper
location of the two (2) 3/8" field drilled holes (C) required to install the starter brackets.
Figure 8S
Ref #
Description
A
Access door/base platform mounting angles shown for reference only.
for Installation details.
B
3
rd
Ring from the Bottom
C
Field Drill Two (2) 3/8" Holes
Содержание PNEG-1451
Страница 2: ...2 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks...
Страница 18: ...18 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...
Страница 19: ...PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks 19 2 66 Corrugated Commercial Hopper Tank 4 9 Rings...
Страница 40: ...40 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...
Страница 70: ...70 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...
Страница 92: ...92 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...