8. 4.00" Corrugation Farm Commercial Hopper Tank (FCHT) 7-9 Rings
100
PNEG-1451
Ladder, Safety Cage and Platform for Hopper Tanks
Eave Platform Mounting Angle Installation
shows the location of the platform mounting angles (B). Each angle must be mounted starting
8" above the top horizontal seam of the second ring with the first mounting angle (B) offset 9-3/8" from
the right hand starter bracket (A). The second mounting angle (B) must be located 56-1/4" from the first
mounting angle (B). The dimensions and locations of these angles are critical for proper fit of all parts. Using
the platform mounting angles (B) as guides, field drill 3/8" holes in the sidewall every 8".
Figure 8H
Ref #
Part #
Description
A
LDR-4347
R.H. Starter Bracket
B
TDP-5008N
Fluorescent Green/Black Platform Mounting Angles (Field drill 3/8" holes on 8" centers.)
C
Roof Ladder
D
Manway Panel
E
18-3/4" Reference
F
44" Typical