18
PNEG-297 Chi-Town Heater
8. HEATER SERVICE
All heaters are constructed of durable weather-resistant materials, so a minimum amount of
service should be required. Before the unit is started for the first time each season there are a
few items that need to be checked out. All damaged parts should be repaired or replaced.
1. Disconnect and lockout power to fan and heater. Open control box lid and inspect all
components for moisture, vibration or rodent damage. Inspect and tighten all loose terminal
connections. Replace any damaged wiring.
2. Remove burner orifice tube and inspect for dirt or foreign material. Clean out if necessary.
3. Inspect holes in burner ring for possible corrosion or plugging with dirt or rust. Clean if
necessary.
4. Be sure primary air inlet screen is intact and clean for proper burn.
5. Check perforated ring on natural gas models to be sure it is clean and no holes are plugged.
6. Inspect flame probe and ignitor and adjust or replace if necessary.
ALWAYS DISCONNECT AND LOCK OUT POWER BEFORE WORKING ON
OR AROUND HEATER