4. Fan Specifications
22
PNEG-163-08
Centrifugal Fan
Inlet Cone Dimensions
Figure 4C
Inlet Cone to Wheel Clearances
Figure 4D
Size
Painted Part #
A
B
C
D
Hole Size
# of Holes
15
C-7743
18.625
4.000
10.375
9.875
0.688
8
18
C-7745
22.750
5.388
12.625
21.750
0.875
16
22
C-7747
27.125
6.750
15.625
26.125
0.875
16
24
C-7749
30.500
7.250
17.000
29.125
1.000
16
27
C-7751
33.125
8.000
18.813
31.750
1.000
16
30
C-7753
36.500
9.000
21.125
35.125
1.000
16
33
C-7754
38.750
10.000
23.063
38.376
1.000
16
Add suffix to painted part # for correct color. “-Y” = YELLOW, “-R” = RED, “-O” = ORANGE
Gap
The “Gap” between the cone and wheel should be equal
distance all around the cone’s inner edge.
Overlap
The “Overlap” of the wheel over the cone should be a
minimum distance to allow free rotation without interference.