1.

Unpack the Auto-Air unit and inspect the machine for visible defects.

2.

Select a mounting configuration.

3.

Secure the machine to the wall or ceiling using the (8) 3/8" x 2" lag bolts provided.

4.

Install pulleys, brackets, hand winches etc. according to your mounting configuration.

5.

Wire the Auto-Air to the appropriate control. (See wiring diagrams on pages 6 & 7.)

6.

Run the machine open to desired opening (2' travel maximum). After machine is at desired
opening, disconnect electric power to the Auto-Air machine.

7.

Remove the (4) screws at the motor end of the Auto-Air Machine and remove the motor end cap.
This will allow access to the “open” limit switch adjustment. (See Figure 1.)

NOTE: The “close” limit switch is preset at the factory and cannot be adjusted.

8.

Adjust the “open” limit by loosening the two screws securing the wheel above the limit switches.

NOTE: After adjustment, be sure to tighten the limit switch adjustment wheel. Failure to
do so can cause damage to the machine.

9.

Install the cable according to your mounting configuration.

10. Manually run the machine closed for approximately 3-6".

11.

In Auto mode, set the controls so that the machine will run “open” to insure that the open limit is
set properly.

Limit Switch Adjustment Wheel

To adjust, loosen the two screws
and turn the wheel

SCREWS

Figure 1

Installation Instructions

Содержание AP Cumberland PNEG-650-1

Страница 1: ...PNEG 650 1 PNEG 650 1 Auto Air Vent Machine DATE 10 06 10 Installation Manual...

Страница 2: ...2 PNEG 650 1 Auto Air Vent Machine Table of Contents Safety 3 4 Installation Instructions 5 Wiring Schematic 6 Control Box Wiring 7 Parts 8 Warranty 9...

Страница 3: ...d may lead to serious injury or death SAFETY GUIDELINES DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury This is the safety alert symbol I...

Страница 4: ...ing condi tion Unauthorized modifications to the machine may impair the function and or safety and affect machine life If you do not understand any part of this manual and need assistance contact your...

Страница 5: ...the Auto Air Machine and remove the motor end cap This will allow access to the open limit switch adjustment See Figure 1 NOTE The close limit switch is preset at the factory and cannot be adjusted 8...

Страница 6: ...o Air Vent Machine NC NO C NC NO C OPEN DEVICE CLOSED DEVICE RED CAPACITOR MOTOR 115V 1 8 AMPS GROUND GREEN WHITE NEUTRAL L1 115V WHITE or YELLOW RED BLACK 1 2 3 Potentiometer Wiring Auto Air Machine...

Страница 7: ...7 PNEG 650 1 Auto Air Vent Machine Control Box Wiring Close Black N White Open Red Red Pot Yellow Wiper Black Pot...

Страница 8: ...8 PNEG 650 1 Auto Air Vent Machine Parts Optional Mounting Plate 53 0017 53 0100...

Страница 9: ...o cost to end user 3 to 5 years end user pays 25 5 to 7 years end user pays 50 7 to 10 years end user pays 75 Warranty prorated from list price 0 to 3 years no cost to end user 3 to 5 years end user p...

Страница 10: ...regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installation occurs Copyright 2010 by The GSI Group Printed in the USA GSI Group...

Отзывы: