74
PNEG-1355 4" & 5" Air Systems
14. COUPLINGS
How to Handle Handling Couplings
1. Couplings are shipped ready-to-install... do not disassemble. To prevent gasket from
slipping out of proper position, always grasp coupling as shown in
. This will save
time by maintaining proper position of gasket and sleeve in relation to shell and flange.
Installing Couplings
1. Confirm pipe O.D. size you intend joining. Each compression coupling has been factory
inspected for proper O.D. size before shipment.
2. Be sure outside surface or pipe is dry, and free of dirt, grease or external burrs. (Burrs &
jagged pipe ends can cut gasket; dirt & grease can cause coupling slippage.)
3. Grasp coupling as shown in
to keep gasket and sleeve (and gasket protector
when used) in separate quadrants, as shown in
. Be sure gasket teeth mesh and
do not overlap.
4. Slide coupling over one pipe past end, then butt pipe ends (a small gap 1/16 maximum at
butt joint will not reduce coupling performance). Slide coupling back until coupling and
gasket protector are centered over joint. Use care when sliding coupling into place...avoid
wrinkling of gasket or gasket protector.
5. The gasket protector provides a bleed path for static electricity.
6. Partially tighten bolts evenly as follows:
1/2 bolt size - 45 ft. lbs. torque
5/8 bolt size - 65 ft. lbs. torque
3/4 bolt size - 95 ft. lbs. torque
(Where SAE GR 5 5/8 bolts are specified tighten to 95 ft. lbs. For couplings with aluminum
shell and inner sleeve do not exceed 40 ft. lbs.)
7. When properly and evenly tightened to the recommended torque the coupling installation
is complete. The top edges of the flanges will touch and flanges appear as a vee when
viewed from the end, as shown in
DO NOT
attempt tightening bolts to flatten
flange faces together, as this exceeds recommended limits.
Figure 14A
Grasp as
shown.
Sleeve
Location
Top of
Flange
Sleeve
Location
Gasket
Location
Содержание 1200 Bu/Hr
Страница 2: ...2 PNEG 1355 4 5 Air Systems ...
Страница 10: ...10 PNEG 1355 4 5 Air Systems 2 DECALS DC 1386 DC 995 N10080 DC 994 DC 995 ...
Страница 15: ...PNEG 1355 4 5 Air Systems 15 NOTES ...
Страница 16: ...16 PNEG 1355 4 5 Air Systems 5 INSTALLATION Air System Tubing Dimensions Figure 5B ...
Страница 28: ...28 PNEG 1355 4 5 Air Systems 9 WIRING Standard Schematic With Digital Amp Meter ...
Страница 29: ...PNEG 1355 4 5 Air Systems 29 9 WIRING Standard Schematic With Analog Amp Meter Using 2EL0273 Control Relay ...
Страница 30: ...30 PNEG 1355 4 5 Air Systems 9 WIRING Schematic With Analog Amp Meter Using HF 7203 Control Relay ...
Страница 31: ...PNEG 1355 4 5 Air Systems 31 9 WIRING Twin Schematic With Digital Amp Meter ...
Страница 32: ...32 PNEG 1355 4 5 Air Systems 9 WIRING Twin Schematic With Analog Amp Meter Using 2EL0273 Control Relay ...
Страница 33: ...PNEG 1355 4 5 Air Systems 33 9 WIRING Twin Schematic With Analog Amp Meter Using HF 7203 Control Relay ...
Страница 40: ...40 PNEG 1355 4 5 Air Systems 12 PARTS LIST 4 700 5 1200 Standard Blower Parts ...
Страница 42: ...42 PNEG 1355 4 5 Air Systems 12 PARTS LIST 4 5 Twin Blower Parts ...
Страница 44: ...44 PNEG 1355 4 5 Air Systems 12 PARTS LIST 5 1700 Hi Capacity Blower Parts ...
Страница 46: ...46 PNEG 1355 4 5 Air Systems 12 PARTS LIST 5 1700 Twin Hi Capacity Blower Parts ...
Страница 48: ...48 PNEG 1355 4 5 Air Systems 12 PARTS LIST 4 5 Blower Filters ...
Страница 50: ...50 PNEG 1355 4 5 Air Systems 12 PARTS LIST 4 5 Airlock Parts ...
Страница 52: ...52 PNEG 1355 4 5 Air Systems 12 PARTS LIST Airlock Inlet Transition Assembly ...
Страница 58: ...58 PNEG 1355 4 5 Air Systems 12 PARTS LIST Standard Control Panel Assembly 230 V 10 30 HP ...
Страница 62: ...62 PNEG 1355 4 5 Air Systems 12 PARTS LIST Standard Control Panel Assembly 230 V 40 HP ...
Страница 64: ...64 PNEG 1355 4 5 Air Systems 12 PARTS LIST Twin Control Panel Assembly 230 V 7 15 HP ...
Страница 68: ...68 PNEG 1355 4 5 Air Systems 12 PARTS LIST Standard Control Panel Assembly 460 V 10 40 HP ...