9 - LCRS485 WIRING DIAGRAM
10 - RATING
PUSH-BUTTON
This button allows us to interact with the Legacy
Connect card as follows:
NOTE: Caution must be taken when manipulating
the electronics while power is on.
NOTE: The push-button is operational only when
the Legacy Connect software is running normally.
For example, if the heartbeat LED isn’t blinking,
you won’t be able to reset the card. In that case, you
may need to power-cycle the host controller.
Press Duration
Action
Less than 1 second
Nothing
Between 1 and 4
seconds
Resets the card
More than 5
seconds
Resets to factory settings.
ALL data on the card is lost.
DIP Switches
The array of DIP switches is not used.
EOL Switch
This switch must always be in EOL position.
RS-485 Connector
This connector can be used to connect additional
RS485 modules when using a controller of the TC5
family.
RS-485 LEDs (LCRS485 model only)
Two LED indicators at the bottom-right of the card
monitor the communication between the controller
(TC5 family) and its auxiliary modules.
LCRXTX Safety Ratings
INPUTS:
Supply Input:
14Vdc +/- 3V, 111mA max
Operating Temperature 0 to 40°C (32 to 104°F)
Storage Temperature in
the cardboard
-20 to 50°C (-4 to 122°F)
Environment Type
Indoor use only
Pollution Degree
2
Installation Category
2
Altitude
2000 Meters Max.
(6561 Ft. Max)
Operating Relative
Humidity (maximum)
0 to 10°C (32 to 50°F)
Non-condensing
10 to 30°C (50 to 86°F) 95%
(± 3 %) Non-condensing
30 to 40°C (86 to 104°F) 95%
(± 3 %) Non-condensing
IP rating (IEC 60529)
0
Nema Rating (Nema 250) 1
Flame Rating (UL94)
5VA V-0
Flame Rating (IEC 60695
or IEC 60707)
FV-0
LCRS485 Safety Ratings
INPUTS:
Supply Input:
14Vdc +/- 3V, 122mA max
Operating Temperature 0 to 40°C (32 to 104°F)
Storage Temperature in
cardboard box
-20 to 50°C (-4 to 122°F)
Environment Type
Indoor use only
Pollution Degree
2
Installation Category
2
Altitude
2000 Meters Max.
(6561 Ft. Max)
Operating Relative
Humidity (maximum)
0 to 10°C (32 to 50°F)
Non-condensing
10 to 30°C (50 to 86°F) 95%
(± 3 %) Non-condensing
30 to 40°C (86 to 104°F) 95%
(± 3 %) Non-condensing
IP rating (IEC 60529)
0
Nema Rating (Nema 250) 1
Flame Rating (UL94)
5VA V-0
Flame Rating (IEC 60695
or IEC 60707)
FV-0
Telecommunication Information
The FCC ID of Espressif Systems Wireless 2.4GHz radio module (ESP32-WROVER-E) is 2AC7Z-ESP32WROVERE.
The IC ID of Espressif Systems Wireless 2.4GHz radio module (ESP32-WROVER-E) is 21098-ESP32WROVERE.
GND B A
GND B A
2 1 2 1
SLAVE PC
2 1 2 1
SLAVE PC
See NOTE 3
See NOTE 3
Ventilation Controller 1
Air Inlet Module 1
Air Inlet Module X (last one)
GND B A
NOTE 3:
• Use a twisted pair shielded cable at 600V and with a temperature insulation of 90C (min). The maximum
length of the cable is 3000m (10,000 ft) and the recommended wire diameter is 1.0mm (18 AWG).
• Use a lightning protection module when running the cable between buildings.
• Interconnect shield wires together.
• Do not ground the shield wire.
NOTE 2:
Consult the Comlink-2
manual (890-00063) about more
air inlet module configurations.
NOTE 1:
No additional wiring.
LCRS485 - No Air Inlet Modules
LCRS485 - With Air Inlet Modules
8 - LCRS485 MODEL