Hexylon High-performance portable meter
28
• Cancel: Closes the options window.
6.1.2.- Options context menu
• Fast: ON/OFF. When the fast scan is enabled
(ON), the meter will not make CBER and VBER
measurements for digital channels, neither V/A
measurements for analog channels. So, only power
and level measurements will be shown.
• Wide outlet: ON/OFF. AEnable this option when
the outlet in your installation has both terrestrial
and satellite bands. So, both bands will be scanned
consecutively. If this options is disabled, only the
selected band will be scanned.
Note: Note that if the selected user profile does not
allow to make measurements in some bands, the
scan will not be done in that band.
• Show all: ON/OFF. When show all is ON, all the
measurements of all the channels are shown. When
it is OFF, you can only see the measurements of the
channel that is being measured in that moment.
• Span full: ON/OFF. When Span full ins ON you
can see all the bars corresponding to all the found
channels. When this option is OFF, only 24 bars are
shown, so it is necessary to scroll to see them all.
• Tilt: ON/OFF. When the tilt option is ON, this
function measures the tilt between the channels
indicated in the labels CH A and CH B. Then you
can see a white line between these two channels
and the tilt measurement on it.
• Attenuation: ON/OFF. When the attenuation
option is ON, the Hexylon measures the attenuation
of the installation relative to a reference point,
usually the head-end output. So, the first thing
you must do is connect the meter to the reference
point and tap on the Calibrate button. In this way,
the equipment will measure and save the level of
all the channels.
Then you must go to all the pints of the installation
where we want to measure and connect the
meter, taking care to have this function ON. The
Hexylon will measure the levels of all the channels
comparing them with the reference ones.
When this option is ON, the bars of the graphic
don’t represent the level or the power of the
channels, but the attenuation of each one of them.
The list shows power (or level) and C/N. In addition,
a green trace is shown in the spectrum. This trace
indicates the levels in the reference point.
• Quality profile: allows to select the quality profile .
• Powering:
-
VDC: Selects the preamplifier powering.
-
DiSEqC (only satellite band): selects the
DiSEqC parameter (Sat A, Sat B, Sat C, Sat
D)
-
Positioner (only satellite band): makes it
possible to control the DiSEqC motors
used to move mobile parabolic antennas.
This function is available in satellite mode
and when the equipment is powering the
LNB.
Halt: This command stops the motor
movement.
East: Allows to move the motor in the
EAST direction. Each click corresponds to
one step in the movement of the motor
(pitch motors). By holding the key down,
successive movement sequences will be
executed until the key is released.
West: Motor movement in the WEST
direction. Each click corresponds to
one step in the movement of the motor
(pitch motors). By holding the key down,
successive movement sequences will be
executed until the key is released.
Store: 8 storage positions are available
to store at up to 8 antenna positions . This
command allows one of 8 positions to be
chosen where the current position of the
antenna will be stored.
Goto: recovers one of the 8 positions
for the antenna that has been previously
stored
-
SCR (only satellite band): Selects the SCR
parameters (multiswitch, standard and
slots) When a slot is enabled (for example
Содержание Hexylon
Страница 2: ......
Страница 69: ...EN 69...
Страница 70: ...Hexylon High performance portable meter 70...
Страница 72: ......
Страница 73: ...901620_901621_1 23_EN...