Contrast (%);
increasing or decreasing the burning percentage. (Value between -0 and 60 in
intervals of 10; value 0 by default).
Forward Feed(dots);
engine forward feeds after printing the label, (value between 0 and
255; by default 56).
.
Disable Backward feed;
it is disabled when the box is checked.. If the box is unchecked,
before printing, the labeller goes backwards according to the engine forward feeds selected in
Forward Feed.
Magnetic Head Distance (dots);
distance between the label's opto-sensors and the burning
line. (Value between 0 and 800; by default 300).
Activate rewind depending on the type of paper;
select the type of paper, Continuous or
Label.
Press
to save changes.
Press
as many times as is needed to go back to the work screen.
7.5.4. Label Calibration.
With this option, the configured parameters are stored in the memory, and the device
performs a calibration of the sensor at the end of the label (opto adjustment). Once the labels
come out, the screen will indicate whether the calibration has been correct.
Press
to save settings.
NOTE:
The length shown will depend on the label's length.
Press
as many times as is needed to go back to the work screen.
7.6.
Weight configuration.
From the "Settings Menu", select the option "Weight Configuration" and press
.