10182 E 06 - 2005
Technical information:
MODULAR VALIDATOR XV
14
2.
FUNCTIONING PRINCIPLES
It has three working modes:
Parallel, Timer and Credit.
To configure the different working modes use the four dipswitches (SW), as shown in the
table:
Working modes
Pa
ra
llel
Time
r
Credit
SW1 OFF ON OFF
SW2 OFF
OFF ON
SW3 OFF
OFF
OFF
SW4 OFF
OFF
OFF
2.1
Parallel mode
The
validator working in Parallel mode gives a signal to identify the coin through one
or more lines when a coin is accepted.
¾
These
validators
have 7 lines that can be:
-
dedicated:
which means that only 6 different coins can be validated as one line is
used to identify each coin.
- binary:
which means various lines can be used to identify a coin, with a maximum
of 32 different coins.
As all the lines in these
validators
are configurable, the 7 lines can be used to
identify coins or other tasks.
¾
The
duration of the pulses
is configurable data.
¾
The
exit assignation
is configurable data.
ON
OFF