GRUNDIG Service
VERTIGA UMS 4600 DEC
2
Es gelten die Vorschriften und Sicherheitshin-
weise gemäß dem Service Manual "Sicherheit",
Materialnummer 720108000001, sowie zusätz-
lich die eventuell abweichenden, landes-
spezifischen Vorschriften!
The regulations and safety instructions shall be
valid as provided by the "Safety" Service Manual,
part number 720108000001, as well as the re-
spective national deviations!
Table of Contents
Page
General Section ................................................ 2
Introduction ..................................................................................... 2
General Notes ................................................................................. 2
Layout of PCBs
and Circuit Diagrams ............................... 3 … 9
Amplifier .......................................................................................... 3
Main PCB ........................................................................................ 4
CD Section ...................................................................................... 7
Exploded Views
and Spare Parts List ............................ 10 … 11
Exploded Views ............................................................................ 10
Spare Parts List ............................................................................ 11
Inhaltsverzeichnis
Seite
Allgemeiner Teil ............................................... 2
Einführung ....................................................................................... 2
Allgemeine Hinweise ....................................................................... 2
Platinenabbildungen
und Schaltpläne ....................................... 3 … 9
Verstärker ....................................................................................... 3
Hauptplatte ...................................................................................... 4
CD-Teil ............................................................................................ 7
Explosionszeichnungen
und Ersatzteilliste ................................ 10 … 11
Explosionszeichnungen ................................................................ 10
Ersatzteilliste ................................................................................. 11
General Section
Introduction
This Supplement of Service Manual describes changed circuit dia-
grams and PCB illustrations. These changed PCBs are used from
serial number 28801 on.
Note:
Basic instructions for servicing are given in the following Service
Manuals:
– Service Manual Safety, Part Number 720108000001
– Service Manual UMS 4600, Part Number 720107740000
General Notes
Before opening the cabinet disconnect the mains plug!
Attention: Observe the ESD safety regulations
Wiring
Before disconnecting any leads and especially the earth connecting
leads observe the way they are routed to the individual assemblies like
the chassis, mains switch panel, keyboard control panel, picture tube
panel, deflection unit, loudspeaker and so on.
On completion of the repairs the leads must be laid out as originally
fitted at the factory to avoid later failures or disturbances.
Carrying out Measurements
When making measurements on semi-conductors with an oscillo-
scope, ensure that the test probe is set to 10:1 dividing factor. If the
previous measurement was made on AC input, please note that the
coupling capacitor in the oscilloscope will be charged. Discharge via
the item being checked can damage the components.
Measured Values
The measured values given in the circuit diagrams are approximates!
Allgemeiner Teil
Einführung
In dieser Service-Manual-Ergänzung sind geänderte Schaltpläne und
Leiterplattenabbildungen dokumentiert. Diese geänderten Leiterplatten
werden ab Seriennummer 28801 verwendet.
Hinweis:
Grundlage für den Service sind folgende Service Manuals:
– Service Manual Sicherheit, Materialnummer 720108000001
– Service Manual UMS 4600, Materialnummer 720107740000
Allgemeine Hinweise
Vor dem Öffnen des Gehäuses zuerst den Netzstecker ziehen!
Achtung: ESD-Vorschriften beachten
Leitungsverlegung
Bevor Sie die Leitungen und insbesondere die Masseleitungen lösen,
muss die Leitungsverlegung zu den einzelnen Baugruppen beachtet
werden.
Nach erfolgter Reparatur ist es notwendig, die Leitungsführung wieder
in den werkseitigen Zustand zu versetzen um evtl. spätere Ausfälle
oder Störungen zu vermeiden.
Durchführen von Messungen
Bei Messungen mit dem Oszilloskop an Halbleitern sollten Sie nur
Tastköpfe mit 10:1 - Teiler verwenden. Außerdem ist zu beachten,
dass nach vorheriger Messung mit AC-Kopplung der Koppelkonden-
sator des Oszilloskops aufgeladen sein kann. Durch die Entladung
über das Messobjekt können Bauteile beschädigt werden.
Messwerte
Bei den in den Schaltplänen angegebenen Messwerten handelt es
sich um Näherungswerte!
Содержание VERTIGA UMS 4600DEC
Страница 4: ...GRUNDIG Service VERTIGA UMS 4600 DEC Hauptplatte Main PCB ...
Страница 5: ...GRUNDIG Service VERTIGA UMS 4600 DEC Hauptplatte Main PCB ...
Страница 6: ...GRUNDIG Service VERTIGA UMS 4600 DEC Hauptplatte Main PCB ...
Страница 7: ...GRUNDIG Service VERTIGA UMS 4600 DEC CD Teil CD Section ...
Страница 8: ...GRUNDIG Service VERTIGA UMS 4600 DEC CD Teil CD Section ...
Страница 9: ...GRUNDIG Service VERTIGA UMS 4600 DEC CD Teil CD Section ...