Comparison and Test specification
Alignment Sequence
Wobbulator Output
connected to
Indicator Connection
Alignment
IF-Filter 12
at MP 502
Probe loose on collector
T502 (MP 503)
(I) For maximum
IF-Filter 11 and 10
at MP 501
(II) and (III) for maximum
IF-Filter 9 and 8
at MP 401
(IV) For symmetry
(V) for Maximum and symmetry
Filters 9 and 8 only in connection
Adjust with the ceramic oscillator.
b)
AM 2,46 MHz-Oszillator
K2-6 turned ON
Alignment Sequence
Signal Generator
coupled to
Alignment Indication
Alignment
2. Oscillator 2.4MHz
2 MHz at MP 401
Output Meter
(VII) Visually to center of
C 459
(VI) for maximum
(VII) Fine adjustment C 459
Removal of Chassis
The notes marked with numbers refer to the expansion sketch embossed
in the bottom of the housing.
a) Pull out the mains cable connector and remove any batteries or the
rechargeable batteries that may have been inserted.
b) Remove the grip shell after loosening the 2 Phillips screws
(1), (2)
.
c) remove the back panel
(3)
.
d) Unsolder the connections of the two loudspeakers, pull off the antenna
cable and unplug the plug connection to the mains transformer.
e) Pull off the knobs and unscrew the 6 nuts of the controller units
(potenciometers)
(4)
.
f) Release the four latches (5), (6), (7), (8) and remove the chassis from the
housing.
Alignment Instructions
All the voltages must be adjusted with the aid of sufficiently accurate
instrument (e.g. GRUNDIG DM 44), and the given voltages should be kept
within the stated tolerances.
I. Adjustment of the Operating Points
No signal, AM button pressed, range switch on KW1 U8 = 9V:
1. Adjust the emitter current of
T 502
with
R 504
so that the voltage drop
across
R506
is
1.3V
2. The control voltage at
PIN 9
of
IC 401
is set to
0.15V
with the
resistance controller
R 409
. An analogue measuring device (e.g.
GRUNDIG UV 5 A) should be used.
3. With the BFO/SSB section switched
ON
, adjust the trimmer
resistor
R 703
so that the voltage drop across
R704
is
4V
.
4. UB = 7.2V:
At a voltage of
7.2 V
, set the display instrument to the battery check
position with the
R 658
controller so that the deflection of the
instrument is on the Dryfit Accu-mark.
II. Adjusting the Charging Voltage UL
With a mains supply of 220V AC and the receiver switched OFF, the
charging voltage UL is to be measured with an equivalent resistance
of 1 kohm and an electrolytic capacitor of 1000 uF (connect in
parallel to the charging contact and minus), the nominal value of
which should be between 9.05 and 9.35 V.
With a voltage of UL < 9.05 V, R 653 (connect separating point X)
must be connected, with a voltage of UL > 9.35 V, R 654 (connect
separating point Y) must be switched on.
III. Frequency Counter
Feed in 32.000MHz/80 mV to St V802 (3) and 2.460 MHz/50 mV to St
V 802 (1) and with C0811 set the display to 30.000 MHz.
IV. AM Alignment
Mod. frequency <1000 Hz
1. AM.IF
a) AM-IF Alignment 460kHz
Содержание Satellit 2400
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......