k
Adjustments
1. CD-Section
Measuring instruments/equipment: Oscilloscope, test CD 5A (part no. 72008-376.00)
Note: Do not turn the variable resistor (laser power adjustment). The laser current is pre-set at the factory.
2. Cassette Deck
Measuring instruments/equipment: Frequency counter, AF-voltmeter, wow and flutter meter,
Fe test cassette 449 (part no. 35079-019.00), torque test cassette 456 (part no. 35079-014.00).
Connect the oscilloscope to testpoint TP1, ground to
TP2.
a.) load the test CD
b.) close the CD door
c.) CD function: Play
Connect the oscilloscope to testpoint TP3, ground to
TP2.
a.) load the test CD
b.) close the CD door
c.) CD function: Play
Adjust VR2 to obtain a clear eye pattern as shown
in the diagram.
Adjust VR3 so that the graph is symmetrical to the
0-line (Vref).
1. Focus Offset
2. Tracking
EF Balance
Adjustment
Preparations
Adjustment Processs
>1V
pp
VOLT/DIV: 0.5V TIME/DIV: 1ms
max. 1.4V
±
0.1V pp
0
(Vref)
V1
V2
V1=V2
VOLT/DIV: 20mV TIME/DIV: 1ms
Connect the frequency counter to the headphone socket.
Insert the test cassette 449,
play 3150Hz.
Insert the torque test cassette 456.
Function: Playback-Start.
Connect the wow and flutter meter to the headphone
socket.
Insert test cassette 449,
play 3150Hz.
Connect the AF-voltmeter to the headphone socket.
Insert test cassette 449,
play 8kHz.
Connect the frequency counter to TP
4
(R/P head).
Insert a recordable cassette.
Function: Record-Start.
Connect the AF-voltmeter via a 1:1000 capacitive voltage
divider to TP
4
(R/P head).
Insert a recordable cassette.
Function: Record-Start
With adjustment control (in the cass.-motor) set the
frequency to 3150Hz
±
0.1%.
Tape tension on:
Playback-Start = 35 - 65g-cm
Fast Forward = 50 - 120g-cm
Fast Rewind = 50 - 120g-cm
Deviation < 0.25% (aurally compensated). Playback
measuring time
≥
30 seconds.
With the head adjustment screw
1
set the left and right channel to
maximum level.
The levels of the two channels must
not differ by more than 3dB.
The oscillator frequency should be 60kHz
±
10 kHz.
Adjust with T301.
The bias voltage is approx. 15mV (measured with a
1:1000 capacitive voltage divider).
Adjust with VR301.
1. Tape speed
2. Take-up torque
on Start
3. Wow and flutter
4. Head gap angle
(Azimuth)
5. Bias frequency
6. Bias voltage
Adjustment
Preparations
Adjustment Process
3. Tuner
Measuring instruments: Standard signal/sweep signal generator, oscilloscope, frequency counter.
1
Adjust T202 to obtain maximum.
At f
u
(526.5kHz) adjust to maximum with T203.
At f
o
(1606.5kHz) adjust to maximum with TC4.
Repeat this adjustment.
At 600kHz
adjust to maximum with L206.
At 1400kHz
adjust to maximum with TC2.
Repeat this adjustment.
With T204 and T201 adjust to maximum.
Repeat this adjustment.
At f
u
(87.5MHz) adjust to maximum with L204.
At f
o
(108MHz) adjust to maximum with TC3.
Repeat this adjustment.
At 90MHz
adjust to maximum with L203.
At 106MHz
adjust to maximum with TC1.
Repeat this adjustment.
Set the frequency to 38kHz
±
100Hz with VR201.
Couple in a sweep signal of 465kHz at L206 (ferrite
aerial) via a loop aerial.
Oscilloscope to TP 2 (IC202, Pin17).
Function switch: AM
MW 526.5kHz, MW 1606.5kHz
Couple in a standard signal frequency at L206 (ferrite
aerial) via a loop aerial. (f
mod
= 1kHz 30%).
Oscilloscope to the headphone socket.
MW 600kHz, MW 1400kHz
Couple in a standard signal frequency at L206 (ferrite
aerial) via a loop aerial. (f
mod
= 1kHz 30%).
Oscilloscope to the headphone socket.
Feed in a 10.7MHz sweep signal to TP 1 (FM-ant.).
Oscilloscope to output TP 2 (IC202, Pin17).
Function switch: FM
FM 87.5MHz, FM 108MHz
Couple in the standard signal frequency to TP 1 (FM-
ant. f
mod
= 1kHz,
∆
f = 22.5kHz).
Oscilloscope to the headphone socket.
FM 90MHz, FM 106MHz
Couple in the standard signal frequency to TP 1 (FM-
ant. f
mod
= 1kHz,
∆
f = 22.5kHz).
Oscilloscope to the headphone socket.
Feed in a standard signal of 98MHz, unmodulated to
TP 1 (FM-ant.).
Frequency counter to TP 3 (IC202, Pin13).
Band switch: FM-Stereo
Adjustment
Preparations
Adjustment Process
1. AM
IF
2. AM (MW)
Oscillator
3. AM (MW)
Aerial bandpass
4. FM
IF
5. FM
Oscillator
6. FM
Aerial bandpass
7. FM
MPX
(Stereo)
4
IC301
SW401-
SW301-
CN301
VR301
T301
TP
CN3
CN4
CN11
IC1
VR2
VR3
J36
R88
R74
TP1
TP2
TP3
1
3
2
L206
VR201
TP
TP
T202
T203
L203
L204
T204
TC1
TC3
TC4
TC2
IC201
IC202
SW201
17
13
1
FM ANT.
T201
Tuner PCB
CD PCB