Select <Upload for __ sec> to set the recording duration after the alarm is triggered. The setting range is from 1
to 99999 seconds.
Select <Upload while trigger is active> to record the triggered video until the trigger is turned off.
NOTE: Please make sure that the local recording (with Micro SD/ SDHC card) is activated so that this function can
be implemented. See section 9.13. 'Recording (on Camera)' for further details.
- Send Message by FTP:
The Administrator can select whether to send an alarm message by FTP when Network Failure is detected.
- Send Message by E-Mail:
The Administrator can choose to send an alarm message by E-Mail when Network Failure is detected.
Save :
After completing all the settings mentioned above, please click on the Save button to save all the settings in this
page.
9.11. Tampering
The Tampering Alarm function helps the IP Camera against tampering such as deliberate redirection, blocking,
spray paint, lens covering, etc. through video analysis and reaction to such events by sending out notifications or
uploading snapshots to the specified destination(s).
Detection of camera tampering is achieved by measuring the differences between the older frames of video
(which are stored in buffers) and more recent frames.
Tampering Alarm :
You will be able to turn the Tampering Alarm function on/off in the Tampering Alarm setting section. The default
setting is: Off.
Tampering Duration :
The Minimum Tampering Duration is the time the video analysis will need to determine whether any camera
tampering has occurred. Defining the Minimum Duration can also be interpreted as defining the Tampering
threshold; longer duration represents a higher threshold. The settable Tampering Duration time range is from 10
to 3600 seconds.