background image

GRUNDFOS 

INSTRUCTIONS

Shipment inspection. ...................................................page 2

Pre-installation checklist. .............................................page 2

Pump installation. ........................................................page 3

Electrical. .....................................................................page 5

Timer control technical data  and application. .............page 5

Timer operation. ..........................................................page 6

Failure to operate. .......................................................page 7

Warranty. .....................................................................page 8

Maintenance-free circulators 
with line cord and optional 
timer control

Installation & operating instructions

Содержание UP15

Страница 1: ...page 2 Pump installation page 3 Electrical page 5 Timer control technical data and application page 5 Timer operation page 6 Failure to operate page 7 Warranty page 8 Maintenance free circulators wit...

Страница 2: ...of the solution Check with manufacturer for information regarding suitability of pumping other fluids System applications UP S 15 series pumps with stainless steel or bronze volutes can be used in bo...

Страница 3: ...x position needs to be changed it is best to do so before installation However if the pump is already installed ensure that the line cord is unplugged and close the isolation valves before removing th...

Страница 4: ...thermal and mechanical stress on the pump Installation requirements 1 Thoroughly clean and flush the system prior to pump installation 2 Do not install the pump at the lowest point of the system wher...

Страница 5: ...d Electrical connection Insert the 115V plug on the line cord from the pump into a properly grounded 115V outlet as shown in Figure 4a 5 Timer technical data TIMER CONTROL Supply Voltage 115 120 VAC 6...

Страница 6: ...ime on the ring 2 Switch on the power supply to the circulator and set the manual switch to the ON position The circulator will now start 3 Set the required ON OFF times on the programming ring by pus...

Страница 7: ...d from system power Remove 2 timer cover screws Gently rotate speed selection stim to desired speed see Figure 7a Re install 2 timer cover screws 9 Troubleshooting When the pump is first started the s...

Страница 8: ...thorized alteration or repair or if the product was not installed in accordance with GRUNDFOS printed installation and operation instructions To obtain service under this warranty the defective produc...