13
English (US)
6.3 Identification
6.3.1 Nameplate
Fig. 16
Example of the nameplate
7. Servicing the product
7.1 Maintaining the product
Under normal operating conditions, the pump is
maintenance-free.
If the pump has been used for liquids other than
clean water, it must be flushed through with clean
water immediately after use. See section
.
T
M
07
05
27
02
1
8
Pos.
Description
1
Pump type
2
Frequency
3
Maximum head
4
Maximum liquid temperature during
continuous operation
5
Product number
6
Production code
7
Full-load current
8
Maximum flow rate
9
Motor insulation class
10
Enclosure class
11
Approvals
12
Motor input power
13
Maximum installation depth
14
Supply voltage
XXXXXX
1
5
12
13
9
14
6
8
2
7
11
3 4
10
SN
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before
starting any work on the product.
Make sure that the power supply
cannot be accidentally switched on.
DANGER
Electric shock
Death or serious personal injury
- If the power cable is damaged, it
must be replaced by the
manufacturer, his service agent or
similarly qualified persons in order
to avoid hazard.
CAUTION
Biological hazard
Minor or moderate personal injury
- Before carrying out maintenance
and service, flush the pump
thoroughly with clean water.
- After dismantling the pump, rinse
the pump parts in clean water.
CAUTION
Sharp element
Minor or moderate personal injury
- Wear protective gloves.
- Never touch the inside of the pump
while the pump is running
CAUTION
Biological hazard
Minor or moderate personal injury
- If a pump has been used for a
liquid which is injurious to health or
toxic, the pump will be classified as
contaminated.
Service must be performed by trained
service persons. Furthermore, all
rules and regulations covering safety,
health and environment must be
observed.