English (GB)
47
14.40 Run start-up guide
This menu is only available in the advanced control panel.
The startup guide automatically starts when you start the pump
for the first time.
You can always run the startup guide later via this menu.
The startup guide will guide you through the general settings of
the pump.
• Language. See section
.
• Select date format.*
See section
14.29 Date and time (Set date and time)
• Set date.*
See section
14.29 Date and time (Set date and time)
• Select time format.*
See section
14.29 Date and time (Set date and time)
• Set time.*
See section
14.29 Date and time (Set date and time)
• Setting of pump
– Go to Home
– Run with Constant curve/Run with Constant pressure.
See section
– Go to "Assisted pump setup".
See section
.
– Return to factory settings.
* Applies only for pumps with advanced functional module, FM
300. For further information, see section
.
14.41 Alarm log
This menu contains a list of logged alarms from the product. The
log shows the name of the alarm, when the alarm occurred and
when it was reset.
14.42 Warning log
This menu contains a list of logged warnings from the product.
The log shows the name of the warning, when the warning
occurred and when it was reset.
14.43 Assist
The menu consist of functions which take you through the steps
needed to set the pump.
14.44 Assisted pump setup
The menu guides you through the following:
Setting of pump
• Selection of control mode. See page
.
• Configuration of feedback sensors.
• Adjusting the setpoint. See page
• Controller settings. See page
.
• Summary of settings.
Example of how to use the "Assisted pump setup" for setting
up the pump to constant pressure:
Grundfos GO
1. Open the "Assist" menu.
2. Select "Assisted pump setup".
3. Select the control mode "Constant pressure".
4. Read the description of this control mode.
5. Select which analog input to use as sensor input.
6. Select sensor function according to where the sensor is
installed in the system. See fig.
.
7. Select electrical input signal according to the sensor
specifications.
8. Select measuring unit according to the sensor specifications.
9. Set the minimum and maximum sensor values according to
the sensor specifications.
10. Set the desired setpoint.
11. Set the controller settings K
p
and T
i
. See the
recommendations in section
.
12. Type the pump name.
13. Check the summary of settings and confirm them.
Advanced control panel
1. Open the "Assist" menu.
2. Select "Assisted pump setup".
3. Select the control mode "Const. pressure".
4. Select which analog input to be used as sensor input.
5. Select the measured parameter to be controlled. See fig.
6. Select measuring unit according to the sensor specifications.
7. Set the minimum and maximum sensor values according to
the sensor specifications.
8. Select electrical input signal according to the sensor
specifications.
9. Set the setpoint.
10. Set the controller settings K
p
and T
i
. See recommendations in
section
14.15 Controller (Controller settings)
.
11. Check the summary of settings and confirm them by pressing
[OK].
Pump variant
Run start-up guide
TPE3, TPE3 D
●
TPE2, TPE2 D
●
Pump variant
Assisted pump setup
TPE3, TPE3 D
●
TPE2, TPE2 D
●