English (GB)
7
4.1 Positioning the pump
Keep the pump as close as possible to the source of hot and cold
water.
For optimum performance, ensure the following:
• A good water flow to the pump.
• Sufficient inlet head. See table and fig. 3.
• Unrestrictive pipes, 22 mm. See fig. 4.
• Provision to prevent air locks. See fig. 4.
Place the pump in a well-ventilated location.
Fig. 3
Inlet head
Fig. 4
Unrestricted pipe
Position the pump horizontally with the outlet ports vertically
upwards to ensure correct operation of the flow switches.
Fig. 5
Positioning the pump
Connect the pump and shower system as shown in fig. 10.
There must be a minimum height between the bottom of the cold-
water storage tank and the highest point of the outlet pipe or the
shower outlet of at least 250 mm. See fig. 6.
Fig. 6
Minimum height difference
Install the pump in accordance with the Water Supply (Water
Fittings) regulations 1999.
Position the pump at the base of the hot-water cylinder. See fig.
7.
Fig. 7
Positioning the pump in relation to hot-water cylinder
For installation within a bathroom, locate the pump in accordance
with local regulations.
Position the pump at least 0.6 metres horizontally away from or 3
metres vertically above floor from any bath, shower tray or basin.
Select a position for installing the pump which affords
easy access for subsequent servicing and
maintenance.
Type
Inlet head [m]
STP, SSP
1-20
STN, SSN
1-8
STR2, SSR2
1-10
STR2 CN, SSR2 CN
1-8
TM
05
69
68
03
13
TM
05
69
76
03
13
=
H
inlet
> 227 litres
(50 gallons)
Do not cover the pump; otherwise, the motor will
overheat.
Place the pump in a frost-free location.
TM
05 696
9
031
3
TM
05
6
967
03
13
T
M
05
69
7
5
03
1
3
The pump may be fitted under a bath, providing this
space is only accessible through the use of a tool.
> 227 litres
(50 gallons)
Min. 250 mm
Содержание SSN
Страница 2: ...2...